Allen-Bradley ArmorStart 290E User Manual page 169

Lt distributed motor controller
Table of Contents

Advertisement

Standards Compliance
Certifications
EtherNet/IP
Web Server
Network Connections
Standards Compliance and Certifications
UL/CSA
UL 508 Industrial Control Equipment –
Suitable for Group Installation
CSA C22.2, No. 14
Communication Ratings
Rated Insulation Voltage
Operating Dielectric Withstand
EtherNet/IP ODVA – Conformance Testing
Ethernet Communication Rate
Ethernet Ports
Ethernet Network Topologies Supported
Device Level Ring Support
Ethernet Connector
Ethernet Cable
IP Configuration
DHCP Timeout
Data
Packet Rate (pps)
Consume Instance (Command)
Produce Instance (Status)
Message Support
Address Conflict Detection (ACD)
Sockets
Security
E-mail
Webpage Features
Concurrent Sessions
Web Server
Concurrent TCP Connections
Maximum I/O Connections (CIP Class 1)
Maximum Concurrent Explicit Messages (CIP Class 3)
Class 1 Connection API
Class 3 Connection API
Request Packet Interval (RPI)
Rockwell Automation Publication 290E-UM001B-EN-P - June 2012
EN/IEC
EN 60947-4-1 Low Voltage Switchgear
CE Marked per Low Voltage Directive 2006/95/EC
and EMC Directive 2004/108/EC
cULus (File No. E3125, Guide NLDX, NLDX7)
EtherNet/IP Interoperability Performance – Per A9 PF 2.1
Beacon Performance, IEEE 1588 Transparent Clock
M12, D code, female, with Ethernet keying, 4 Pin
IP v4 Address Conflict Detection for EtherNet/IP devices
Support Simple Mail Transfer Protocol (SMTP)
Maximum of 15 encapsulated messages over both TCP and UDP
Supports up to 2 Class 1 CIP connections [Exclusive owner (data) or
listen-only]. One connection per PLC. Listen only connection requires a
Specifications
Other Agencies
CCC (Pending)
KCC
C-Tick
ODVA for EtherNet/IP and DeviceNet
250V
UL/NEMA: 1500V AC, IEC: 2000V AC
10/100 Mbps, half or full-duplex
2 (embedded switch)
Star, Tree, Linear, and Ring
Category 5e: Shielded or unshielded
Static, DHCP, or BootP
30 s
Transported over both TCP and UDP
500 packets-per-second (2000 μs), Tx
500 packets-per-second (2000 μs), Rx
Default of 3 words (Instance 150)
Default of 14 words (Instance 152)
Unicast or Multicast
150 maximum
Login and password configurable
Status, diagnostics, configuration
20
HTTP 1.1
data connection to be established.
6
2...3200 ms
100...10 000 ms
20 ms default (2 ms minimum)
Chapter 6
169

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Armorstart 291eArmorstart 294e

Table of Contents