General Settings: Interface items introduction:
Interface items
Configuration
Enable Loop
Disabled/Enabled
Protection
Transmission
1-10 second
Time
Shutdown Time
0-604800 second
Port Configuration: Interface items introduction:
Interface items Configuration
Port
1- n
Enable
Select/not select
Action
Shutdown Port
Shutdown Port and
Log
Log Only
Tx Mode
Disabled/Enabled
5.2.2.9 Spanning Tree
A. STP Configuration
Enter [Spanning Tree] → [Bridge Settings] navigation
column, configure the system spanning tree on this page,
prevent loop. Enable RSTP protocol defaulted by system.
All configured parameters are applied to all STP of switch
configuration.
Set relevant parameters, click [Save] button to complete
the spanning tree protocol bridge configuration.
Click [Reset] button to restore the default settings.
Introduction
Controls whether loop protection is enabled on this switch
port.
The interval between each loop protection PDU sent on
each port. Valid values are 1 to 10 seconds.
The period (in seconds) for which a port will be kept dis-
abled in the event of a loop is detected (and the port action
shuts down the port). Valid values are 0 to 604800 seconds
(7 days). A value of zero will keep a port disabled (until
nextdevice restart).
Introduction
The switch port number of Switch.
Controls whether loop protection is enabled on this switch
port.
loop is detected on a port, Shutdown the Port
Loop detected, shutdown port and log
Loop detected, not shutdown port and log
Select the port is send port of protected PDU, or the receiv-
ing end, Enabled as the sender, Disabled receiving end
BCD-RGD-804P-MT
Factory setting
Disabled
5
180
Factory setting
1-n
Select
Shutdown Port
Enabled