Interface items Introduction:
Interface items Configuration
Port
1-n (Number of physical ports) Number for Switch To configure the port
Policy ID
0-255
Action
Permit/Deny
Rate Limiter ID Disabled/0-16
Port Redirect
Disabled/port Number
Mirror
Disabled/Enabled
Logging
Disabled/Enabled
Shutdown
Disabled/Enabled
State
Disabled/Enabled
Counter
ACL Rate Limiter Configuration
Enter [ACL configuration] → [Rate Limiters] navigation column,
is the ACL rate limiter configuration of port, The system sup-
ports 16 broadband strategy, speed range: 0-3276700 / PPS or
0,100,200,300 ... between 10000000kbps.
26
BCD-RGD-804P-MT
Introduction
Select the policy to apply to this port
Select filter out traffic is forwarded or blocked
Select which rate limiter ID to apply on this port
Select which port frames are redirected on. The allowed
values are Disabled or a specific port number and it
can't be set when action is permitted. The default value
is "Disabled".
Frames received on the port are mirrored or not mir-
rored.
Frames received on the port are stored in the System
Log or not logged.
Frames received on the port are stored in the System
Log or not logged.
If a frame is received on the port, the port will be dis-
abled or Enabled
When you select Enabled, when changing the port you
are using ACL user module, open ports
When you select Disabled, when changing the port you
are using ACL User Module, shut down the port
Counts the number of frames that match this ACE.
Factory setting
1-n
0
Permit
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Enabled
0
www.bcdvideo.com