Components - Effecta KOMPLETT III Installing, Maintenance, Service, Assembly

20-25-35 kw
Hide thumbs Also See for KOMPLETT III:
Table of Contents

Advertisement

Components

The shunt valve
The shunt valve is connected to the boiler or accumulator tank.The shunt valve
controls the heat supply from the boiler to the heating circuits of the house.
Heat regulation
The boiler is equiped with its own heat regulator. In the "Shunt control" menu you
can choose how to control the heat in the house. More on how to regulate the
heat is found on pg. 36.
The thermostatic mixer valve
The mixing valve is used to ensure that the temperature of the hot water in your
shower and elsewhere in the house is comfortable. Set the system to the tem-
perature you want by turning the thermostat between +/-. If you have a Komplett
Light the mixer valve is mounted on the accumulator tank.
Feeder
The feeder is either internal or external on the boiler. The feeder controls the
amount of pellets fed to the burner.
The burner
The burner is mounted on either the right or left side. The fuel from the feeder is
ignited and combusted, which heats up the water in the boiler.
Turbulators
Within the tubes in the heat exchanger hang the turbulators. The turbulators function
is to transfer heat from the flue gas to boiler water. They must always be placed in
the boiler. If the flue gas temperature in the chimney is too low, the turbulators can
be cut off to increase the temperature.
Draft stabiliser
The draft stabiliser gives the boiler stabile draft conditions, this improves
combustion and efficiency.
Hot water coil
Within the boiler is a hot water coil that heats up the water for the house. The
water you can drain from the boiler depends on the boiler temperature, the mount
of flow you through and which effect the boiler is set to. We recommend a flow
of 12-42l/min in the taps. In the Light model there is no coil, here you heat your
water in a external water heater.
The sealings
The seals on the hatches must be checked every year. If the hatches do not seal
properly, the efficiency and the combustion process of the boiler will deteriorate.
Dust and ash can also leak out during cleaning.