Function Suction System - Effecta KOMPLETT III Installing, Maintenance, Service, Assembly

20-25-35 kw
Hide thumbs Also See for KOMPLETT III:
Table of Contents

Advertisement

Function suction system

If the boiler is equipped with a suction
system the menu on the right is shown.
In the "INSTALLATION" menu you need to
change settings in order to customize the
system for your energy needs.
Function
The suction system includes a number of
important components. On the storage
there is a suction motor which builds up a
underpressure in the hose connected to the
filling outlet of the storage. The proximity
sensor senses the need for filling pellets,
when set time between fillings is reached,
the safety ball valve closes and the suction
system is allowed to start, with a delay of
60sec. The suction motor tries to fill the storage by running for 15min - resting for 15min - running
for 15min and so on. If the storage hasn´t been filled after 80mins the boiler alarms "Suction
time". A filling normally takes 15-20min suction time.
Time between fillings
How often your system chooses to fill is down to your settings in the menu. We recommend you
set it as far a part you can, but with a margin so that the storage never is empty. A full storage
contains roughly 200kWh of energy. If your house consumes 8kWh, the storage last for about
24hours.
Night blocking
If the boiler is placed so you can hear it, you can block refilling of pellets certain times of the day.
In the "SERVICE" menu you can set when refilling is allowed(On) and when its not allowed(Off).
Then refilling isn´t allowed between these hours, unless there is a risk of downtime of the burner,
in which case the filling cycle runs even though you have turned it off.
Fill storage
If you activate "Fill Storage", the storage will be filled regardless of settings. This function is
used when you first start the system or if the storage is empty. Note that if the storage has been
emptied, the feeder must be filled again. In the "Installation" menu you find the function "Fill
feeder". The boiler must be in mode "Off" for this function.
Proximity sensor
The proximity sensor is mounted from the factory. When the
light is on there are pellets near the top of the storage. If the
sensor needs to be adjusted it should be done when the storage
full. Find the setting for On/Off on the screw. Adjust it so that
light is lit.
20
Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - 0300 - 22320 - info@effecta.se
Consumption
kW/h
kW/day
5
120
10
240
15
360
20
480
25
600
8 h
Filling interval
Night blockage
Yes
Fill storage
No
Time filling, h
30
15
10
8
6
I n -
s t a l -
lation
is
the

Advertisement

Table of Contents
loading

Table of Contents