Tuning the boiler

Electrical heater
You must choose which effect you want your electrical heater is to use if activated. You can
choose between 3-6-9 kW (9000W). Note that you need to specify the main fuse of the
house, if you only have 16A it is not sure you can run the el.heater in full effect, 9kW, then you
need to install power monitors. Set which temperature you want the el.heater to start if there
is a disruption or if the pellets has ran out. Set the temperature 5°C below the burners start
temperature so that it does not activate unnecessarily. If you have a Light, the boiler has no
electrical heater.
Cleaning
In the "Service" menu you set how often the boiler should be cleaned. For minimal
maintenance it should be actived as much as possible. You can also block the cleaning during
some times of the day/night.
Clock
In the "Other" menu you can set the clock. The clock controls functions such as night blocking.
Shunt control
In the shunt control you can choose between room sensor/outdoor sensor/both or constant.
You can activate 3 different shunt groups.
- When you choose both, the room sensor only works as a logger and a regulator of the indoor
temperature. Choose the appropriate curve for your house. The curve might have to be ad-
justed several times before you find the ideal indoor temperature.
- When you choose Room sensor, the desired temperature is set on the included thermostat.
There is no temperature scale on the sensor so you change the temperature on the boiler.
Place the sensor in an open area of the house where there is no interference from other heat
sources. In order to get the right temperature in each room you may have to adjust each radia-
tor separately.
- When you choose more than one shunt group, each one must be adjusted with the included
room sensors.
More info about the shunt control is on pg 36-38.
Energy saver
In the shunt control there is also a possibility to lower the temperature certain time of the day or
some days in the week.
Suction system
If the boiler has a suction system you need to set the time when it is allowed/not allowed to
retrieve pellets from the storage. You find the settings on pg 20.