Menu system
1. Flue gas temp.
2. Flow temp.
3. Boiler temp.
4. CO2
5. Flame sensor
6. El. heater
7. Igniter
Operation
Heating system
Other
Burner
Fan
Feeder
Temperature set
Information
Service
Installation
Fan
Fan burner
Fan boiler
Fan lowspeed
Fan burner lowspeed
Fan boiler lowspeed
Fan larm
Tacho
Fan larm
Feeder
Start dose
Support dose
Pellets diameter
mm
Run start dose
Run supp. dose
Run oper. dose
Temperature set
Boiler temp G1
Stop
Start
Acc.tank high G6
Acc.tank low G5
Stop G5
Max G6
Start G1
Loading pump Start
Loading pump Stop
Information
Number starts
Igniter hours
Oper. pellets
Clean number
Reset info
Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - 0300 - 22320 - info@effecta.se
Current temperature of the flue gases G2
Current temperature of the flow G7
Current boiler temperature G1
Current CO2 value
Current strength of flame in boiler.
Current effect of the el. heater in the boiler.
Current burner mode.
Settings for burner.
Settings for heating systems.
Settings for other functions
Burner mode (on/off)
>
>
Settings for the fan of the burner.
>
Settings of the augers feeding control. (password needed)
>
Settings for the burners operation temp.
>
Operations log of the burner.
>
Menu for burner service settings.
>
Settings for automatic cleaning etc.
Setting of the burner fan in operation mode.
Setting of the boiler fan in lowspeed.
On
Activating low speed (On/Off)
Settings of burner fan in lowspeed.
Settings of boiler fan in lowspeed.
Activates Tacho mode
5s
Time before alarm triggers
Start dose size, measured according to (pg.33.)
Size of support dose, dose is given between ignition and running mode.
Size of the pellet
Test run of start dose for measuring. Only available in burner mode off.
Test run of supp. dose for measuring. Only available in burner mode off.
Test run of operation dose for measuring. Only available in burner mode off.
Shows the boiler temp, start/stop sensor with overheating function.
Temperature when the burner goes to standby mode.
Temperature when the burner starts up from standby mode.
When loading acc. tank, sensor G6 is installed at the tank top of the primary
tank. The sensor starts the burner at set temp. (Only shown if mounted)
Temperature when burner stops.
Maximum allowed temperature G6, tank overheated.
Temperature when burner starts.
Temperature when loading pump starts
Time loading pump runs
Displays the number of burner starts been done
Displays the number of hours ignitor has been lit.
Displays the number of hours the burners been running.
Displays the number of times the AERO unit has cleaned the burner.
Resets the information above.