Menu system
Function
Flame sensor
Igniter
Feeder
Fan
Compressor
Solenoid valve
Test air clean.
Convection cleaning
Shunt motor (+/-)
El. heater
Radiator pump
Loading pump
Boiler fan
Shunt motor 2 (+/-)
Radiator pump 2
Shunt motor 3 (+/-)
Radiator pump 3
Fill storage
R27
R28
VridM

Alarms

Ignition failure
Start phase failure
Oper. phase failure
Alarm at disruption
Alarm
Burner
Alarm
Ignition
Alarm
Flue gas
Alarm
Boiler temp.
Alarm
Flow.
USB connection
Don´t interrupt the download. This will damage all software in the boiler.
Make sure that your USB-stick contains the correct files. There should be an
*.hex- and *.bin file on the USB stick.
In order to upgrade the software in the boiler you need to connect a USB-memory to the boiler.
There is an connection cable located behind the cover plate .
Turn off the power to the boiler. Insert the USB-memory, then turn the power back on. The
controller starts downloading the new software. It´s important not to interrupt the updating
procedure, this will damage the controller. Wait until the picture of flags comes up on the display .
Disconnect the USB-memory. Your boiler is now updated.
32
Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - 0300 - 22320 - info@effecta.se
Function test of the flame sensor. Must be illuminated to test function.
Activates ignitor, the fan starts at 60% to protect the ignitor.
Activates the auger/feeder.
Activates the fan.
Activates compressor for cleaning.
Activates/opens solenoid valve for cleaning.
Activates and tests the full AERO cleaning cycle.
Activates the cleaning of the convection.
Activates the shunt motor, open or close, +/-.
Activates electrical heater.
Activates the radiator pump.
Activates the loading pump for another unit such as Laddomat.
Activates and tests boiler fan.
Activates the shunt motor 2.
Activates the radiator pump 2.
Activates the shunt motor 3.
Activates the radiator pump 3.
Activates suction system.
Number of failed ignitions
Number of Start phase failure
Number of Operation phase failure
There has been a problem during operation phase. The most likely problem is that the pellets have
run out. The flame sensor can also be covered by soot.
The burner has missed the ignition phase. The most likely problem is a poorly adjusted starting dose.
Also check the ignitor in the function test.
The flue gas temperature has been above 320°C. This is an extremely high temperature, please
check that the automatic cleaning is working (function test) and that the boiler is clean. Also check
the flue gas sensor. Contact installer.
The temperature of the boiler has been above its max value. Normally this can happen from
the heat after the combustion cycle. Try to lower the stopping temperature if the problem
reoccurs.
Alarm from the Tachometer on the burner fan, check for faults on the fan.