Effecta KOMPLETT III Installing, Maintenance, Service, Assembly page 41

20-25-35 kw
Hide thumbs Also See for KOMPLETT III:
Table of Contents

Advertisement

Change of the igniter
Cut the power to the boiler. Loosen the main cable to the burner, the cable to the flame sensor
and the compressed air hose to the burner.(1)
Remove the four wing nuts (2) which are holding the rear housing against the end plate of
the outer combustion tube. Angle the rear housing and pull it upwards/backwards so that the
fall shaft loosens from the inner tube. Then detach the pipe to compressed air by unscrewing
the quick connector on the outside of the rear housing. Then disconnect the ignition element
wires on the terminal block located under the metal lid of the electrical console (3). Remove
the ignition device from the rear housing by taking out the two screws on the bottom of the
burner (4). Ignition element clamp is removed (5) and the element is pulled out of the square
tube.
Slide the new element in the square tube. Push so it lies on the outer edge of the square tube
(6).
Install the clamp and tighten the screws with moderate force, so that the element is not going
to fly back and forth.
Insert the ignition device in the rear housing. The cables should be pulled out through the fan's
cable access. Connect the cables on the console. Secure the two cables to each other with
a cable tie. Reassemble in reverse order, wait to fasten ignition device in the burner until the
burner is mounted together with the outer tube. Push the ignition device to the burner tube
and tighten the two bolts. Check that the square tube is in the middle of the hole in the inner
tube.
Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - 0300 - 22320 - info@effecta.se
When you reassemble the ignition
device make sure to push it all
the way to the front of the burner
tube. If there is a gap, ignition and
cleaning is impaired.
41