Documentation of settings

Before you as a installer commision the boiler system we ask you to fill out the different
values set in the menus. This is important for the future services and makes it easier in the
communication between the customer and the installer and between the installer and Effecta.
Settings for the system
Menu
Temperature set
Temperature set
Fan
Fan
Fan
Advance
Advance
Advance
El.heater
El.heater
Feeder
Feeder
Installation
Installation
Installation
Shunt group 1
Shunt group 2
Shunt group 3
Parameters, operation with an accumulator tank
Menu
Temperature set
Temperature set
Temperature set
Temperature set
Temperature set
Temperature set
Type plate
Tillverkare / Manufactory
Effecta Energy Solutions AB
Hersteller / Fabricants
Modell / Model
Effecta Komplett III
Typ / Modéle
Effecta Komplett III Light
Effekt / Heat output
20
25
Heizleistung /Puissance nominale (kW)
Godkänd enl. / Approved by
Zugelassen nach / Approuvé á
Miljöklass / Emission class
Emissionsklasse / Classe d'émission
Max drifttryck / Max pressure
Max Betriebsdruck / Pression maximum (bar)
Max drifttemp. / Max temp. (C)
Max. Betriebstemp. / Temp d'opération max
Elinstallation / Electrical supply
230 / 380 ~ 50Hz
Elektroanschluss / Branchement électrique
El-patron / Electrical heater (kW)
0
El-Patrone / El-cartouche
Vattenvolym / Water volume
99
Wasserinhalt / Contenance d`eau (litre)
Bränsleklass / Fuel class
EN Plus / DIN Plus
Brennstoffklasse / Classe d' carburant
Tillverknings nr / Manufacturing number
Herstell Nr / Numéro de fabrication
Tillverknings år. / Manufacturing year
2014
2015
2016
2017
2018
Tillverknings månad / Manufacturing month
1
2
3
4
5
6
7
8
9
10
Effecta AB - Sweden - Kungsbacka - www.effecta.se
Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - 0300 - 22320 - info@effecta.se
Parameters
Start temp. burner
Stop temp. burner
Burner fan, speed
Burner fan, lowspeed
Boiler fan, operation speed
Fan start
Oper. phase start
Fan Pulse 1-2-3
Temperature el.heater
Effect el.heater
Operation dose
Start dose
Effect high and low, if activated
Fan pre oper.
Fan low pre oper.
Sensor, heat curve, room temp, adjust.
Sensor, room temp., cylinder
Sensor, room temp., cylinder
Parameters
Acc.tank high G6
Acc.tank low G5
Stop G5
Max G6
Start G6
Max G1
Komplett III
1. Radiator fram / Flow
Vorlauf / Depart radiateurs
2. Radiator retur* / Return*
Rücklauf* / Retour radiateurs*
(*standard mounting of the pex tube)
3. Kallvatten in / Cold water in
Kaltwasser / Eau Froide (ECS)
4. Varmvatten ut / Hot Water out
35
Warmwasser / Eau Chaude (ECS)
EN-303-5
Komplett III Light
5
5. Avluftning / Venting
Entlüftung / Ventilation
3
100
3 - 9
183
4. 3.
2.
1.
5.
11
12
Value
Value