Menu system
Service
Clean at
On
Off
Interval
Number clean
Clean pause
Cleaning conv.
Flue gas
Max time burner
External control
Installation
Advanced
Fill feeeder
Effect high speed
Effect low speed
Testblow
Phase out
Fan pre oper.
Fan low pre oper.
Clean phase out
Flame sens
Quickstart
Lambda
Time between filling
Night block
Fill storage
Flame sensor
Level start
Level oper.
Time oper
Time phase out
Snabbstart
Temp down
Temp down
Lambda
co2 level
Calibrate
Advance
FanPulse 1
FanPulse 2
FanPulse 3
Fan start
Oper. start
Burner starts
Igniter hours
Oper. pellets
Number clean
Ign. Sequence 1
Ign. Sequence 2
Ign. Sequence 3
30
Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - 0300 - 22320 - info@effecta.se
phase out.
Option if cleaning should be done prior to or after the running cycle.
Time when AERO cleaning is allowed (ON).
Time when AERO cleaning is not allowed (OFF).
Setting of how many cleaning cycles.
Setting of the amount of blows in each cycle.
Time between each blow in a cleaning cycle.
Settings for cleaning the convection
Temperature for the cleaning to start.
Max operation time of the burner before pause with AERO cleaning
Off
Choice of external START/STOP control to the boiler
>
Advanced settings (requires password)
Activates feeder for 15min. Only in mode Burner Off.
Setting for the burners effect in high speed.
Setting for the burners effect in low speed.
Seconds the fan blows before ignition phase.
Seconds the ignitor is active after the flame sensor has approved start value.
The fan speed before operation phase.
The fan low speed before operation phase.
Time that the fan afterblows before standby or cleaning.
>
To flame sensor menu
>
To quick start menu
>
To Lambda menu
Time between fillings
Time when filling is not allowed.
Manually filling of the storage
Set value where the burner goes from ignition mode to operation mode.
Lowest approved value in operation mode. If lower: "ALARM BURNER"
Time before "ALARM BURNER" when flame sensor lower than level oper.
Time before the fan goes to max speed.
°C
Degrees temp shall fall before burner goes to quick start.
min
The time in which the temp. shall fall (X) degrees before burner activates quickstart.
Settings of required oxygen level in combustion.
%
Possible calibration of lambda +/-.
%
Fan speed in Fan Pulse 1.
Fan speed in Fan Pulse 2.
Fan speed in Fan Pulse 3.
Time before the fan starts.
Time before the burner goes into operation.
Number of registrated ignitions.
Number of hours the igniter has operated
Number of hours the burner has operated.
Number of starts the compressor has done
Registration of which Ign. sequence ignition occurs.