Cleaning system burner

Remember to always cut the power to the boiler before starting any work on it.
Function
On the side of the burner there is a compressor with a compressed air hose mounted which
cleans the burner. Compressed air is blown into the burner. When the cleaning starts the com-
pressor builds up a pressure in the hose which then is released with a pressure shock and the
ashes are removed from the burner. You can set how often, how long and during which times
cleaning is allowed in the "SERVICE"menu.
Compressor
The compressor builds up a pressure in the air hose.
The compressor has a life span of about 2500h, and
can then drop in pressure head or leak air. Then there
is a renovation set to renovate the compressor.
Compressed air hose
The hose is only used to store air before it is
released into the burner.
Pressure gauge
Shows the pressure in the hose. It is also an
indicator when or if you need to adjust the pressure
for optimisation.
Pressure switch
Stops the compressor when targeted pressure
is reached, there is a adjustment screw which is
preset on 7 bar.
1
Compressor
2
Capacitor
3
Pressure switch
4
Pressure gauge
5
Solenoid valve
6
Compressed air hose
Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - 0300 - 22320 - info@effecta.se