  • Page 2: Introduction

    Introduction ▀ We at Effecta would like to thank you for putting your trust in us when choosing your new boiler. The ”Effecta 222” has been developed to give you maximum performance, comfort and quality. In order to get the best results from your boiler, we suggest that you follow the recommendations in this installation guide.
  • Page 3: Warranty

    Effecta. If a faulty product is detected, Effecta is entitled to replace it with a new or reconditioned product of the same or a similar type. Effecta is liable for the costs of any servicing or repairs. Effecta gives a 5 year guarantee on the remaining components.
  • Page 4: Table Of Contents

    Automatic cleaning Hot water Valve combination Shunt valve Cleaning Electrical connection Electrical connection Electrical connection Technical data Hydraulic scheme Draft stabiliser Trouble shooting CE-Mark Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - +46(0)300 - 22320 - info@effecta.se...
  • Page 5: In General

    ▀ In general The Boiler Effecta 222 is a boiler which is to be fueled with wood pellets. No other kind of fuel is allowed to be used. Not logs or oil. Disassembly and disposal It will be many years before your Effecta boiler is worn out, but it is important that you follow the regulations in force at the time concerning disassembly and disposal of your boiler.
  • Page 6: To The Installer

    To the installer ▀ It is time to install the Effecta 222 pellet boiler. Please follow the examples we provide for a safe installation. After installation, be sure to instruct the customer on how the heating system and the boiler work, in order to avoid unnecessary complications in the future.
  • Page 7: System Components

    The temperature that leaves the boiler should be in the range of 160-230°C if there is condensation in the chimney the temperature must be higher. To achieve a higher flue gas temperature you can cut the turbulators 5cm. Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - +46(0)300 - 22320 - info@effecta.se...
  • Page 8: Control Panel

    ▀ Control panel Overheating protection Cuts power when the temperature exceeds 95ºC Display Status of the heating system Keypad Maneuvering in the menus Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - +46(0)300 - 22320 - info@effecta.se...
  • Page 9: Placement Of The Components

    Hole for burner Control panel Expansion / hotwater Power for burner* Hole for measuring instrument Flame sensor* Power for auger* *Only with Effecta Supra/Aero. Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - +46(0)300 - 22320 - info@effecta.se...
  • Page 10: Service And Cleaning

    Also clean the flue tube that goes to the chimney, when it is not certain that the chimney sweep do it. Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - +46(0)300 - 22320 - info@effecta.se...
  • Page 11: Automatic Cleaning

    Flipper Flips when the magnet motor activates. Magnet motor Lyfting shaft Flipper Suspension Turbulator Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - +46(0)300 - 22320 - info@effecta.se...
  • Page 12: Hot Water

    Also note that the electrical connection (open / close) will be different depending on which side the return pipe is placed. Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - +46(0)300 - 22320 - info@effecta.se...
  • Page 13: Cleaning

    1,5 tons consumption of pellets. Note that there can be glow a long time after burning Nuts Soot hatch Suspension turbulators Ashbox (inside of the door) Turbulators Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - +46(0)300 - 22320 - info@effecta.se...
  • Page 14 Before shifting a e-prom make sure to write down all the settings that has been done to the boiler. This since all the changes that has been done will be lost. Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - +46(0)300 - 22320 - info@effecta.se...
  • Page 15: Electrical Connection

    CLOSE BROWN RADIATOR PUMP BLUE YELLOW GREEN EXTERNAL FAN JOINT EARTH CENTER SOCKET EARTH CENTER PIN MICRO SWITCH FEEDER MOTOR IGNITOR FAN MOTOR E-PROM Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - +46(0)300 - 22320 - info@effecta.se...
  • Page 16: Electrical Connection

    Effecta Pellets 222. In the menu ”Electrical heater”, set the maximum load you can have on the main fuses. *Current sensor is optional Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - +46(0)300 - 22320 - info@effecta.se...
  • Page 17: Technical Data

    Technical data ▀ 1702 1545 Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - +46(0)300 - 22320 - info@effecta.se...
  • Page 18: Hydraulic Scheme

    Hydraulic scheme ▀ Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - +46(0)300 - 22320 - info@effecta.se...
  • Page 19: Draft Stabiliser

    The draft varies a lot depending on the chimney, weather and also if the burner is running or not. This means that the hatch can be open a lot, a little or closed, depending the situation. Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - +46(0)300 - 22320 - info@effecta.se...
  • Page 20: Trouble Shooting

    The burner doesn´t start - Micro switch broken - Check switch - Overheating protection activated - Reset protection - No fuel - Fill up with fuel Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - +46(0)300 - 22320 - info@effecta.se...
  • Page 21: Ce-Mark

    Del 1: Allmänna fordringar Kopplat till maskin och LVD. SS-EN 50081-2 För emission-industri ( EMC –standard) SS-EN 50082-2 För immunitet-industri (EMC- standard) Kungsbacka 2004-12-12 Erik Andersson Effecta Pannan AB Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - +46(0)300 - 22320 - info@effecta.se...