Components

Laddomat 21-100 or equivalent
A Laddomat valve should always be mounted between boiler and
tank. It´s described further on page 12.
Automatic Shunt
The installation of a shunt automatic system on the radiator
circuit is always recommended. The automatic system senses
the temperature in a suitable location in the house and adjusts
the incoming temperature on the radiator circuit accordingly.
This measure can reduce your wood consumption by as much as
25 % and will improve your heat comfort level..
Expansion Vessel
The expansion vessel normally is tested for 6 bars. Highest
working temperature is 99°C. The vessel has a prepressure
of 2,5 bar. The volume should be approx. 10-12% of the total
volume of the system. An open vessel should have a volume of
5% of the total.
Safety Valve
The safety valve will release when pressure exceeds 1,5 bars.
When it opens, water will drip out of it and the pressure goes
down. Remember that the system is designed for a maximum
pressure of 1,5 bars, and shall under no circumstances be under
higher pressure.
Shunt valve
The shunt valve is to be mounted on the radiator circuit, and it´s
designed to mix the accumulator water and the return water from
the radiator to get the right temperature indoor. If mounting an
automatic shunt valve, read it´s instructions.