Boiler room

It is time to install the Effecta Komplett III pellet boiler. Please follow the examples we provide
for a safe installation. After installation, be sure to instruct the customer on how the heating
system and the boiler works, in order to avoid unnecessary complications in the future.
Set up
The boiler is positioned so that the
surface temperature of flammable
building material does not exceed
80°C. The boiler should be positioned
at least 10 cm (1) from the wall. If the
distance between the flue tube and
flammable wall is less than 30 cm
an ignition protective covering
must be used (4). In order to
clean the boiler, a minimum
clear space of 1 metre (2)
is required in front of the
boiler. A passage with a
minimum width of 0.5m (3)
is required along one of
the long sides of the boiler.
Check the regulations of your
country in order to place the
pellet hopper an approved
distance from the boiler.
Boiler room
The boiler must be installed in a boiler room or boiler house. The ceilings and walls must
be fitted with ignition protective covering and the floor must be made of non-combustible
material. Minimum ceiling height in the boiler room is 2 metres. The boiler room or boiler house
must be equipped with a fresh air intake with the minimum dimensions 150 x 150 mm(5.) or
with a sufficiently large free sectional area to avoid low pressure in the boiler room. It must be
impossible to close the air intake.
Chimney
The chimney should have enough area to manage the effect from the boiler. At standstill the draft
should be between 5-10pa. It is important that the chimney is tested and approved by a HETAS
approved installer before a new boiler is installed. If the chimney is tall and has a lot of mass to
heat up there is a risk of condensation. Measure the temperature 1m down from the top when the
burner is running, the temperature should be 70°C.
Read more about the chimney on pg 42.