Config/Set Push Button

Configuration
The DG safety relay has two push buttons on the front faceplate. These
buttons are labeled Config/Set and Sel./Save.
These push buttons allow you to do the following:
• Configure the DG safety relay to perform a safety function
• Confirm the existing safety functions
• Reset the DG safety relay
• Report the fault code
The DG safety relay has two modes of operation: run and configuration. The
functions that the push buttons perform depend on the operating mode and
length of time the push button is pressed.
• Short: The button is pressed less than one second.
• Long: The button is pressed for longer than three seconds, but shorter
than 10 seconds.

Run Mode

Button Press
Function
Short
The indicators show the configuration of the DG safety relay.
• Press once to see the configuration (see
• Press a second time to see the time delay setting (see
• Press a third time to see the status of the wiring terminals again (see
After about 20 seconds of inactivity, the indicators revert to the wiring terminal status.
Long
The DG safety relay enters Configuration mode. The 13/14, 23/24, and X2 outputs turn OFF, if
they are ON.
After 60 seconds of inactivity, the indicators revert to the wiring terminal status. Changes to the
configuration are not saved.
IMPORTANT After changes to the hardware configuration of the DG safety relay or the
GuardLink circuit, power must be cycled to the DG safety relay, the GuardLink
circuit, and to the EtherNet/IP interface.