Allen-Bradley SensaGuard 440N-Z21SS2H-AS Installation Instructions Manual

Allen-Bradley SensaGuard 440N-Z21SS2H-AS Installation Instructions Manual

Rectangular flat pack

Advertisement

SensaGuard
TM
Rectangular Flat Pack
Installation Instructions
Certifications
IMPORTANT:
SAVE THESE INSTRUCTIONS FOR FUTURE USE
440N-Z21SS2H-AS
Allen-Bradley 440N-Z
Note: Refer to Technical Specifications for Certification information and ratings.
PN-114371 dir 10000182958 ver 00

Advertisement

Table of Contents
loading

Summary of Contents for Allen-Bradley SensaGuard 440N-Z21SS2H-AS

  • Page 1 SensaGuard Rectangular Flat Pack Installation Instructions Certifications IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE 440N-Z21SS2H-AS Allen-Bradley 440N-Z Note: Refer to Technical Specifications for Certification information and ratings. PN-114371 dir 10000182958 ver 00...
  • Page 2: Table Of Contents

    SensaGuard Installation Instructions This instruction sheet is available in multiple languages at www.rockwellautomation.com/literature. ENGLISH: Select publication language and type "SensaGuard" in the search field. Dieses Instruktionsblatt kann in mehreren Sprachen unter www.rockwellautomation.com/literature gelesen werden. GERMAN: Bitte Ihre Sprache anwählen und "SensaGuard" im Suchfeld eintippen. Ces instructions sont disponibles dans différentes langues à...
  • Page 3: Installation Instructions

    Operating Temperature -10…+55°C (+14…+131°F) Operating Humidity 5% -95% relative Washdown rating NEMA 3, 4X, 12,13, IP 69K Shock & Vibration IEC68-2-27 30 g, 11 ms/IEC 68-2-6 10…55Hz Radio Frequency IEC 61000-4-3 Allen-Bradley 440N-Z IEC 61000-4-6 PN-114371 dir 10000182958 ver 00...
  • Page 4: Protection

    SensaGuard Installation Instructions Protection Short-Circuit Protection Incorporated Current limitation Incorporated Overload Protection Incorporated False Pulse Protection Incorporated Transient Noise Protection Incorporated Reverse Polarity Protection Incorporated Overvoltage protection Incorporated Thermal shutdown/restart Incorporated Dimensions - mm (inches) 18.54 (0.73) 10.67 (0.42) 24.99 20.65 24.99 20.65...
  • Page 5: Minimum Distance Between Sensors

    24V DC or each other. Cycle power. Amber 1 Hz Flash margin indicator Sensor is reaching max. sensing Flash safe, OSSD active distance; re-align sensor with actuator Allen-Bradley 440N-Z Note: Refer to Technical Specifications for Certification information and ratings. PN-114371 dir 10000182958 ver 00...
  • Page 6: Troubleshooting

    SensaGuard Installation Instructions Troubleshooting Series Circuit Pink Gray Brown Pink Gray Brown Pink Gray Brown Pink Gray Brown Pink Gray Brown White Note: Refer to Technical Specifications for Certification information and ratings. PN-114371 dir 10000182958 ver 00...
  • Page 7 SensaGuard Installation Instructions Unit Response Time (does not include safety relay response time) Allen-Bradley 440N-Z Note: Refer to Technical Specifications for Certification information and ratings. PN-114371 dir 10000182958 ver 00...
  • Page 8: Application Wiring Examples

    SensaGuard Installation Instructions Application Wiring Examples Brown Yellow Pink Gray Blue Brown Brown Yellow Yellow Pink Gray Pink Gray Blue Blue Brown Yellow Pink Gray Blue Brown Pink Gray Blue Brown Yellow Pink Gray Blue Brown Brown Yellow Yellow Pink Pink Gray Gray...
  • Page 9 Pink Gray Blue Brown Yellow Pink Gray Blue Brown Yellow Pink Gray Blue Brown Yellow Pink Gray Blue Brown Yellow Pink Gray Blue Allen-Bradley 440N-Z Note: Refer to Technical Specifications for Certification information and ratings. PN-114371 dir 10000182958 ver 00...
  • Page 10 SensaGuard Installation Instructions Application Wiring Examples Blue Blue Blue Blue Yellow Yellow Yellow Yellow Brown Brown Brown Brown Brown Brown Brown Yellow Brown Yellow Blue Blue Blue Blue Note: Refer to Technical Specifications for Certification information and ratings. PN-114371 dir 10000182958 ver 00...
  • Page 11 Blue Blue Blue Yellow Yellow Brown Yellow Yellow Brown Brown Brown Brown Brown Yellow Brown Brown Yellow Yellow Yellow Blue Blue Blue Blue Allen-Bradley 440N-Z Note: Refer to Technical Specifications for Certification information and ratings. PN-114371 dir 10000182958 ver 00...
  • Page 12: List Of Recommended Relays

    SensaGuard Installation Instructions List of recommended relays MSR126, MSR127, MSR123, MSR124, MSR131, MSR138, MSR211, MSR121, MSR200 Family (Except MSR210), MSR300 Family, SmartGuard, 1791 DS DeviceNet™ Safety I/O. Relay must have light curtain inputs. Check the machine is isolated and stopped whenever the interlocked guard door is open.

Table of Contents