Komatsu PW160-7H Operation & Maintenance Manual page 253

Wheeled excavator
Table of Contents

Advertisement

MAINTENANCE
CLEAN INSIDE OF COOLING SYSTEM
Immediately after the engine is stopped, the coolant is at
a high temperature and the radiator is under high internal
pressure.
If the cap is removed to drain the coolant in this condi-
tion, there is a hazard of burns. Wait for the temperature
to go down, then turn the cap slowly to release the pres-
sure before removing it.
Cleaning is carried out with the engine running. When
standing up or leaving the operator's seat, raise the
safety lock lever to the LOCK position.
For details of starting the engine, see "CHECK BEFORE
STARTING ENGINE (145)" and "STARTING ENGINE (158)"
in the OPERATION section.
There is danger of touching the fan if the undercover is
left removed.
Never enter behind the machine when the engine is run-
ning.
Clean the inside of the cooling system, change the coolant and
replace the corrosion resistor agent KI according to the table
below.
Kind of coolant
Permanent type antifreeze
(All season type)
Non permanent type antifreeze
containing ethylene glycol
(winter, one season type)
When not using antifreeze
Stop the machine on level ground when cleaning or changing the
coolant.
Use a permanent type of antifreeze.
If, for some reason, it is impossible to use permanent type anti-
freeze, use an antifreeze containing ethylene glycol.
Super Coolant (AF-ACL) has an anti-corrosion effect as well as
an antifreeze effect.
The ratio of antifreeze to water depends on the ambient tempera-
ture, but to obtain the corrosion resistance effect, a minimum ratio
of 30% by volume is necessary.
In areas where the water is hard, add Komatsu genuine corrosion
resistor agent KI. One packet of corrosion resistor agent contains
100g. The standard density of the mixture should be 7 g/litres.
PW160-7H VEAM390100
WARNING
Cleaning inside of cooling system
and changing coolant
Every year (autumn) or every
2000 hours whichever comes first
Every 6 months (spring, autumn)
(Drain antifreeze in spring,
add antifreeze in autumn)
Every 6 months or every 1000
hours whichever comes first
SERVICE PROCEDURE
Adding corrosion resistor agent KI
Every 1000 hours and when cleaning
the inside of the cooling system and
when changing coolant.
253