Cleaning the fiber connector and fiber cable using ZW-XCL
For ZW-7000 Series
1
Taking out a cleaner
Don't dirty the top of the cleaner, and take one cleaner
from the package.
2
Cleaning the fiber connector face of the Controller side.
Open the shtter of the fiber connector, and then wipe the fiber's face around thres reciprocating.
3
Cleaning the Sensor Head connection of the fiber ca-
ble
Remove the cap from the fiber cable and wipe the entire
end surface of the fiber connector with about 3 passes.
Clean around the 2 guide pins as well.
Important
• The cleaner can only be used one time. Reusing the cleaner may result in dirt or scratches on the end surface,
causing malfunctions or measurement errors. Discard after use.
• When using a fiber cleaner, be sure to use the cloth (white end surface) on the cleaning section to clean.
60
Installation
ZW-7000/5000
User's Manual