Clearing the Bank Settings
Select a bank and initialize its settings.
1
Set the operating mode to the FUNC mode.
3-2 Switching operation modes p.90
2
Select the bank data.
Select the bank data from the Multi View
Explore, and select [Initialize] from the right-click
menu.
Note
The bank settings can also be cleared by the operating keys on the Sensor Controller.
Initializing Settings p.245
Setting the Bank Mode
Select the bank contents to be obtained from the settings or judgment value.
All bank data will be initialized when the bank mode is switched.
Item
Setting item
Sensor settings
Bank mode
1
Set the operating mode to the FUNC mode.
3-2 Switching operation modes p.90
Multi View Explore
→ Edit pane
168
Saving The Settings
Setting value
Description
Normal (default
Sensing setting, measurement setting and I/O setting that are set in the FUNC
value)
mode are regarded as bank data. The number of banks is up to eight.
Judgment
Only the threshold value under the measurement setting is regarded as bank
value
data. Other values are the same for all banks. The number of banks increases
up to 32.
: [System] (double-click)
: [Sensor Settings] icon (
)
ZW-7000/5000
User's Manual