Omron ZW-7000 Series User Manual page 109

Confocal fiber type displacement sensor
Hide thumbs Also See for ZW-7000 Series:
Table of Contents

Advertisement

Item
Setting item
Data logging
Data interval
conditions
Number of
logging data
OUT1
OUT2
OUT3
OUT4
2
Click the [Logging start] button to start
internal logging.
A confirmation message is displayed. Click
[Yes] to start internal logging.
When the label insert mode is OFF, the internal
logging data is automatically cleared before
internal logging is started.
Once internal logging starts, another internal
logging cannot be started until it ends.
Note
• Starting internal logging can also be executed by No-protocol communications or parallel I/O.
• For assigning of OUT1 to OUT4, refer to the following:
"2-1 Parallel I/O connection" described in Displacement Sensor ZW-7000 series Confocal Fiber Type
Displacement Sensor User's Manual for Communications Settings (Z363).
3
After internal logging ends, click the [Save to
file (Sensor → PC)] to output the data to a
file.
A CSV format file in the following format is
output. Unit of each output values are the
following:
Measure value: nm
Amount of emitted light: 0.01% (0.01 to
100.00%)
Amount of received light: Luminance level (0 to
4095)
ZW-7000/5000
User's Manual
Range
Description
1 to 1000
Set the data storage interval.
If "1" is set , all measured data is stored, and "2" is set, one
measurement value is stored every two measurement.
If 0 is set, data is saved only when the hold value is applied.
1 to 2000000
Set the number of data to store for the data that is assigned
to each OUT.
OFF/ON
Set whether to store the measurement results for OUT1.
OFF/ON
Set whether to store the measurement results for OUT2.
OFF/ON
Set whether to store the measurement results for OUT3.
OFF/ON
Set whether to store the measurement results for OUT4.
Performing internal logging
107