Parameter List - Mitsubishi Electric FR-D720-0.2K-G Instruction Manual

S-pm geared motor drive unit fr-d700-g series
Table of Contents

Advertisement

Parameter list

4.2
Parameter list
4.2.1
parameter list
For simple variable-speed operation of the drive unit, the initial setting of the parameters may be used. Set the necessary
parameters to meet the load and operational specifications. Parameter setting, change and check can be made from the
operation panel.
Parameter
Name
Initial Value
Extended function display
160
9999
selection
REMARKS
  indicates simple mode parameters.
 The parameters surrounded by a black border in the table allow its setting to be changed during operation even if "0" (initial
value) is set in Pr. 77 Parameter write selection.
Parameter
Name
Function
1
Maximum setting
2
Minimum setting
4
Multi-speed setting (high speed)
5
Multi-speed setting (middle speed)
6
Multi-speed setting (low speed)
7
Acceleration time
8
Deceleration time
9
Electronic thermal O/L relay
10
Coasting speed
11
DC injection brake operation time
13
Starting speed
15
Jog speed setting
16
Jog acceleration/deceleration time
17
MRS input selection
Acceleration/deceleration reference
20
speed
22
Stall prevention operation level
24
Multi-speed setting (speed 4)
25
Multi-speed setting (speed 5)
26
Multi-speed setting (speed 6)
27
Multi-speed setting (speed 7)
54
Setting Range
Remarks
9999
Displays only the simple mode parameters
0
Displays simple mode + extended parameters
Minimum
Refer
Initial
Setting Range
Setting
to
Value
Increments
Page
0 to 12000r/min/
1r/min
3000r/min
87
0 to 8000r/min

0 to 3600r/min/
87
1r/min
0r/min
0 to 2400r/min

0 to 12000r/min/
89
1r/min
3000r/min
0 to 8000r/min

0 to 12000r/min/
89
1r/min
1500r/min
0 to 8000r/min

0 to 12000r/min/
89
1r/min
300r/min
0 to 8000r/min

0 to 3600s
0.1s
5s
97
0 to 3600s
0.1s
5s
97
Rated motor
0 to 500A
0.01A
101
current
0 to 3600r/min/
1r/min
90r/min
110
0 to 2400r/min

110
0 to 10s
0.1s
0.5s
0 to 1800r/min/
1r/min
15r/min
99
0 to 1200r/min

0 to 12000r/min/
1r/min
150r/min
91
0 to 8000r/min

0 to 3600s
0.1s
0.5s
91
0, 2, 4
1
0
119
30 to 12000r/min/
1r/min
3000r/min
97
20 to 8000r/min

83
0 to 200%
0.1%
150%
0 to 12000r/min/
1r/min
9999
89
0 to 8000r/min
, 9999

0 to 12000r/min/
1r/min
9999
89
0 to 8000r/min
, 9999

0 to 12000r/min/
1r/min
9999
89
0 to 8000r/min
, 9999

0 to 12000r/min/
1r/min
9999
89
0 to 8000r/min

, 9999
 Symbol in the Remarks column.
...Specifications differ according to the date assembled. Refer to page 294 to check the SERIAL number.
 These instruction codes are used for parameter read and write by using Mitsubishi inverter protocol with the RS-485 communication.
(Refer to page 184 for RS-485 communication.)
 "" indicates valid and "" indicates invalid of "control mode-based correspondence table", "parameter copy", "parameter clear", and "all parameter clear".
Customer
Parameter
Remarks
Setting
1
2
4
5
6
7
8
9
10
11
13
15
16
17
20
22
24
25
26
27
Instruction Code
Parameter
Read
Write
Extended
Copy
Clear
All Clear
01
81
0
02
82
0
04
84
0
05
85
0
06
86
0
07
87
0
08
88
0
09
89
0
0A
8A
0
0B
8B
0
0D
8D
0
0F
8F
0
10
90
0
11
91
0
14
94
0
16
96
0
18
98
0
19
99
0
1A
9A
0
1B
9B
0