Parameter List - Mitsubishi Electric F700 Instruction Manual

Hide thumbs Also See for F700:
Table of Contents

Advertisement

Parameter List

3.1 Parameter List
3.1.1
Parameter list
In the initial setting, only the simple mode parameters are displayed.
Set Pr. 160 User group read selection as required.
Parameter
Name
User group read
160
selection
REMARKS
⋅ The parameters marked
⋅ The parameters marked with
value) is set in Pr. 77 Parameter write selection.
⋅ Parameters for the option are displayed only when the option unit is installed.
⋅ The instruction codes (hexadecimal) for "read" and "write" on the right of the parameter number are those used to set the
parameter via communication. "Extended" indicates the setting of the extended link parameter. (Refer to page 156 for
communication)
Instruction
Code
Function Parameters
Read
Write
00
0
Torque boost
0
80
01
1
Maximum frequency
0
81
02
2
Minimum frequency
0
82
03
3
Base frequency
0
83
04
Multi-speed setting (high
4
0
speed)
84
05
Multi-speed setting (middle
5
0
speed)
85
06
Multi-speed setting (low
6
0
speed)
86
07
7
Acceleration time
0
87
08
8
Deceleration time
0
88
09
9
Electronic thermal O/L relay
0
89
0A
DC injection brake operation
10
0
frequency
8A
0B
DC injection brake operation
11
0
time
8B
0C
DC injection brake operation
12
0
voltage
8C
0D
13
Starting frequency
0
8D
0E
14
Load pattern selection
0
8E
0F
15
Jog frequency
0
8F
Jog acceleration/deceleration
10
16
0
time
90
11
17
MRS input selection
0
91
38
Initial
Setting
Value
Range
9999
9999
are the simple mode parameters.
in the table allow its setting to be changed during operation even if "0" (initial
Name
Only the simple mode parameters can be displayed.
Simple mode and extended mode parameters can be
0
displayed.
Only parameters registered in the user group can be
1
displayed.
Minimum
Setting Range
Setting
Increments
0 to 30%
0.1%
0 to 120Hz
0.01Hz
0 to 120Hz
0.01Hz
0 to 400Hz
0.01Hz
0 to 400Hz
0.01Hz
0 to 400Hz
0.01Hz
0 to 400Hz
0.01Hz
0 to 3600/ 360s
0.1/0.01s
0 to 3600/ 360s
0.1/0.01s
0 to 500/0 to 3600A
0.01/0.1A
0 to 120Hz, 9999
0.01Hz
0 to 10s, 8888
0.1s
0 to 30%
0.1%
0 to 60Hz
0.01Hz
0, 1
1
0 to 400Hz
0.01Hz
0 to 3600/360s
0.1/0.01s
0, 2
1
Remarks
Refer
Initial
Customer
to
Value
Setting
Page
6/4/3/2/
53
1.5/1%
120/60Hz
62
0Hz
62
50Hz
64
50Hz
67
30Hz
67
10Hz
67
5s/15s
74
10s/30s
74
Rated inverter
78
output current
3Hz
81
0.5s
81
4/2/1%
81
0.5Hz
76
1
60
5Hz
69
0.5s
69
0
87

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents