(2)
Using the setting dial like a potentiometer to set the speed
Operation example Changing the speed from 0r/min to 1800r/min during operation
Operation
1.
Screen at power-ON
The monitor display appears.
2.
Press
to choose the PU operation mode.
3.
Press
to choose the parameter setting
mode.
4.
Turn
until "
5.
Press
to read the present set value.
"
"(initial value) appears.
6.
Turn
to change it to the set value "
7.
Press
to set.
8.
Change Pr. 161 to the setting value of "
in the similar manner. (Refer to step 4 to 7.)
9.
Mode/monitor check
Press
twice to choose the monitor/speed
monitor.
10.
Press
to start the drive unit.
11.
Turn
until "
The blinking speed is the set speed. You need
not press
.
REMARKS
If the display changes from blinking "1800" to "0", the setting of Pr. 161 Speed setting/key lock operation selection may not be "1".
Independently of whether the drive unit is running or at a stop, the speed can be set by merely turning the dial.
When the speed is changed, it will be stored in EEPROM as the set speed after 10s.
NOTE
When setting speed by turning setting dial, the speed goes up to the set value of Pr. 1 Maximum setting (initial value:
3000r/min). Adjust Pr. 1 Maximum setting setting according to the application.
Setting the parameter unit and operation panel
" (Pr. 160) appears.
".
Blink Parameter setting complete!!
"
Blink Parameter setting complete!!
" appears.
Display
PU indicator is lit.
PRM indicator is lit.
(The parameter number read previously
appears.)
The speed blinks for about 5s.
4
243