Appendix 1 Options And Products Available On The Market - Mitsubishi Electric FR-D720-0.2K-G Instruction Manual

S-pm geared motor drive unit fr-d700-g series
Table of Contents

Advertisement

Appendix 1 Options and products available on the market

Name
Parameter unit
(Eight languages)
Enclosure surface operation
panel
Parameter unit
connection cable
DIN rail attachment
Heatsink protrusion
attachment
AC reactor
DC reactor
EMC Directive compliant EMC
filter
EMC filter installation
attachment
Radio noise filter
Line noise filter
Filterpack
Brake resistor
High-duty brake resistor
Brake unit
Discharging resistor
Power regeneration common
converter
Stand-alone reactor dedicated
for FR-CV
High power factor converter
292
Model
FR-PU07
Interactive parameter unit with LCD display
This operation panel enables drive unit operation and
FR-PA07
monitoring of rotation speed, etc. from the enclosure surface
Cable for connection of operation panel or parameter unit
FR-CB20
 indicates a cable length. (1m, 3m, 5m)
FR-UDA01 to 03
Attachment for installation on DIN rail
This attachment dissipates about 70% of the drive unit's heat
FR-E7CN01, 02
by setting the drive unit heatsink to be protruded from the back
side of the enclosure.
FR-HAL
For harmonic current reduction and drive unit input power
FR-HEL
factor improvement.
An EMC filter that complies with the EMC Directive (EN61800-3
SF1306, SF1309
C3)
An attachment used to mount an EMC compliant EMC filter
FR-E5T
(SF1309) to a drive unit.
FR-BIF
For radio noise reduction (connect to the input side)
FR-BSF01
For line noise reduction
FR-BLF
A Filterpack that contains a power factor improving DC reactor,
FR-BFP2
common mode choke, capacitive filter (radio noise filter) in one.
MRS type, MYS
For increasing the regenerative braking capability (permissible
type
duty 3%/6%ED)
For increasing the regenerative braking capability (permissible
FR-ABR
duty 10%/ 6%ED)
For increasing the braking capability of the drive unit (for
FR-BU2
highinertia load or negative load)
GZG, GRZG type
Brake unit, electrical-discharge resistor and resistor unit are
used in combination
FR-CV
Unit which can return motor-generated braking energy back to
FR-CVL
the power supply in common converter system
The high power factor converter switches the converter section
ON/OFF to reshape an input current waveform into a sine
FR-HC2
wave, greatly suppressing harmonics. (Used in combination
with the standard accessory.)
Applications, Specifications, etc.
Applicable
Drive Unit
Applicable for all
models
Applicable for all
models
Applicable for all
models
Applicable for the
certain capacities
Applicable for the
certain capacities
Applicable for the
certain capacities
Applicable for the
certain capacities
Applicable for the
certain capacities
Applicable for all
models
Applicable for all
models
For the 0.4K or
higher
Applicable for the
certain capacities
Applicable for the
certain capacities
Applicable for the
certain capacities
Applicable for the
certain capacities
Applicable for the
certain capacities

Hide quick links:

Advertisement

Table of Contents
loading