Speed setting by external terminals
(1) Main speed
? S et the main speed as a base, and increase it with the RH signal and decrease it with the RM signal.
The method to set the main speed in each of the operation modes below is as follows.
PU operation mode / NET operation mode
External operation mode / PU/External combined operation mode 2 (Pr. 79 = "4")
PU/External combined operation mode 1 (Pr. 79 = "3")
(2) Acceleration/deceleration operation
The set speed (set by remote setting) and the operating speed change according to the setting of the following
parameters.
Speed type
acceleration/deceleration
Set speed
Pr. 44 / Pr. 45
Operating speed Pr. 7 / Pr. 8
RM signal
(deceleration)
RH signal
(acceleration)
Set speed
Speed increases according to
acceleration time set in Pr. 44.
Operating
speed
Speed increases according to
acceleration time set in Pr. 7.
(3) Speed setting storage function
The remotely set speed is stored, held, or cleared. When the drive unit is turned ON again and the operation is resumed,
the speed within the parentheses will apply.
Pr. 59 setting
1
Stored (stored set speed)
2
Cleared (main speed)
3
Cleared (main speed)
Storage conditions
The remotely set speed is stored at the point when the start signal (STF or STR) turns OFF. The remotely set speed is
stored every minute after turning OFF (ON) both of the RH and RM signals. Every minute the latest stored speed value is
compared with the second latest one. When they are not equal, the latest one is written in the EEPROM. The writing in the
EEPROM is not effected by the ON/OFF status of the RL signal.
94
Operation mode
Parameter used for
ON
Speed decreases according to
deceleration time set in Pr. 8.
Power OFF
Increases/decreases according to the setting of Pr. 44 / Pr. 45 set by remote
setting.
Increases to / decreases from the set speed according to the setting of Pr. 7 / Pr.
8.
ON
Time
Speed decreases according to
deceleration time set in Pr. 45.
Time
STF/STR signal OFF
Held (stored set speed)
Held (stored set speed)
Cleared (main speed)
Main speed
Digital setting (using the operation panel)
Analog input via terminal 2 or 4
Analog input via terminal 4 (AU signal ON)
Description