Speed setting by external terminals
(2) Jog operation from PU
Select Jog operation mode from the operation panel and the parameter unit (FR-PU07). Operation is performed only while
the start button is pressed.
Operation
1.
Confirmation of the operating status indicator
and operation mode indicator
The monitor mode should have been
selected.
The drive unit should be at a stop.
2.
Press
to choose the PU Jog operation
mode.
3.
Press
.
While
is pressed, the motor rotates.
The motor runs at 150r/min. (Pr. 15 initial
value)
4.
Release
[When changing the speed of PU Jog operation]
5.
Press
to choose the parameter setting
mode.
6.
Turn
until Pr. 15 Jog speed setting appears.
7.
Press
to show the present set value.
(150r/min)
8.
Turn
to set the value to "
(300r/min)
9.
Press
to set.
10.
Perform the operations in steps 1 to 4.
The motor rotates at 300r/min.
92
Drive unit
R/L1
Three-phase AC
S/L2
power supply
T/L3
Operation panel
Press
Release
".
Blink...Parameter setting complete!!
U
V
Motor
W
Display
Stop
PRM indicator is lit.
(The parameter number read previously
appears.)