Mitsubishi Electric FR-D720-0.2K-G Instruction Manual page 72

S-pm geared motor drive unit fr-d700-g series
Table of Contents

Advertisement

Parameter list
Parameter
Name
Function
Pr.CH
Initial value change list
PM
PM parameter initialization
AUTO
Automatic parameter setting

Differ according to capacities. (2.2K or lower/3.7K)

The initial value differs according to the voltage class. (200V class/400V class)

The parameter number in parentheses is the one for use with the parameter unit (FR-PU07).

Write is disabled in the communication mode (Network operation mode) from the PU connector.

These parameters are communication parameters that are not cleared when parameter clear (all clear) is executed from RS-485 communication. (Refer to
page 184 for RS-485 communication.)

The capacity of the S-PM geared motor is initially set to the next smaller size than the capacity of the drive unit.

While the parameter settings copied to the latest version drive unit (manufactured in April 2018 or later) are verified against the parameter settings copied
to the parameter unit (FR-PU07) from the older version drive unit (manufactured in March 2018 or earlier) after the parameter settings are copied, a
verification error about parameters marked with 7 will be displayed. However, these errors are not faults.
Press "0" on the parameter unit to proceed the verification. (For information about Parameter copy and Parameter verification, refer to the Instruction
Manual of the parameter unit.)
Copying the parameter settings from the latest version drive unit to the older version drive unit is prohibited. If doing so, reset the copied parameter
settings by performing Parameter clear or All parameter clear.

Settings "8009" and "9009" can be displayed after offline auto tuning is performed.
REMARKS
 The unit for parameter setting and its setting range can be changed from "r/min" to "Hz". Use Pr. 144 to change the setting.
 With operation panel, the value up to 9999 can be set. With parameter unit (FR-PU07), up to the highest value in the setting
range can be set.
 If a value exceeding the upper speed limit of the motor is set, the actual operation will be limited at the maximum rotation
speed.
68
Minimum
Refer
Initial
Setting Range
Setting
to
Value
Increments
Page
248
6004, 8009, 9009
1
6004
73
*8
239
Customer
Parameter
Remarks
Setting
Pr.CH
PM
AUTO
Instruction Code
Parameter
Read
Write
Extended
Copy
Clear
All Clear
F4
Parameter list
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents