Mitsubishi Electric FR-D720-0.2K-G Instruction Manual page 217

S-pm geared motor drive unit fr-d700-g series
Table of Contents

Advertisement

Communication operation and setting
 Parameter
Parameter
Register
41000 to
0 to 999
C2 (902)
C3 (902)
125 (903)
C4 (903)
C5 (904)
C6 (904)
126 (905)
C7 (905)
C42 (934)
C43 (934)
C44 (935)
C45 (935)
 Fault history
Register
40501
Fault history 1
40502
Fault history 2
40503
Fault history 3
40504
Fault history 4
40505
Fault history 5
40506
Fault history 6
40507
Fault history 7
40508
Fault history 8
Data
Definition
No fault
H00
present
H10
E.OC1
H11
E.OC2
H12
E.OC3
H20
E.OV1
H21
E.OV2
H22
E.OV3
H30
E.THT
H31
E.THM
* Refer to page 253 for details of fault description.
214
Parameter Name
Refer to the parameter list (page
41999
54) for the parameter names.
Terminal 2 speed setting bias
41902
(Speed)
Terminal 2 speed setting bias
42092
(Analog value)
Terminal 2 speed setting bias
43902
(Terminal analog value)
Terminal 2 speed setting gain
41903
(Speed)
Terminal 2 speed setting gain
42093
(Analog value)
Terminal 2 speed setting gain
43903
(Terminal analog value)
Terminal 4 speed setting bias
41904
(Speed)
Terminal 4 speed setting bias
42094
(Analog value)
Terminal 4 speed setting bias
43904
(Terminal analog value)
Terminal 4 speed setting gain
41905
(Speed)
Terminal 4 speed setting gain
42095
(Analog value)
Terminal 4 speed setting gain
43905
(Terminal analog value)
41934
PID display bias coefficient
42124
PID display bias analog value
PID display bias analog value
43934
(Terminal analog value)
41935
PID display gain coefficient
42125
PID display gain analog value
PID display gain analog value
43935
(Terminal analog value)
Definition
Fault code list
Data
Definition
H40
E.FIN
H52
E.ILF
H60
E.OLT
H61
E.SOT
H70
E.BE
H80
E.GF
H81
E.LF
H90
E.OHT
H91
E.PTC
HB0
E.PE
Read/
Write
The parameter number + 41000 is the register
Read/write
number.
Read/write
Read/write The analog value (%) set to C3 (902) is read.
The analog value (%) of the voltage applied to the
Read
terminal 2 is read.
Read/write
Read/write The analog value (%) set to C4 (903) is read.
The analog value (%) of the voltage applied to the
Read
terminal 2 is read.
Read/write
Read/write The analog value (%) set to C6 (904) is read.
The analog value (%) of the current (voltage)
Read
applied to the terminal 4 is read.
Read/write
Read/write The analog value (%) set to C7 (905) is read.
The analog value (%) of the current (voltage)
Read
applied to the terminal 4 is read.
Read/write
Read/write The analog value (%) set to C43 (934) is read.
The analog value (%) of the current (voltage)
Read
applied to the terminal 4 is read.
Read/write
Read/write The analog value (%) set to C45 (935) is read.
The analog value (%) of the current (voltage)
Read
applied to the terminal 4 is read.
Read/write
Read/write
Being 2 bytes in length, the data is stored as
Read
"H00".
Read
Refer to the lowest 1 byte for the error code.
Read
Read
Performing write using the register 40501 batch-
Read
clears the fault history.
Read
Set any value as data.
Read
Data
Definition
HB1
E.PUE
HB2
E.RET
HC0
E.CPU
HC4
E.CDO
HC5
E.IOH
HC7
E.AIE
HC9
E.SAF
HD0
E.OS
HE6
E.PID
HF5
E.5
Remarks
Remarks

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents