4.20.4 Magnitude of speed change setting (Pr. 295)

Setting this parameter increases the magnitude of speed which changes according to the rotated amount of the setting
dial, improving operability.
Parameter
Name
Number
Magnitude of speed change
295
setting
The above parameter can be set when Pr. 160 Extended function display selection = "0". (Refer to page 161.)
 Valid when the frequency increments or machine speed increments is selected with Pr. 37 or Pr. 144. (Refer to page 132.)
(1)
Basic operation
When a value other than "0" is set in Pr. 295, the minimum varying width when the set speed is changed by the setting dial can
be set.
For example, when "10" is set in Pr. 295, one click (one dial gauge) of the setting dial changes the speed in increments of
10r/min20r/min30r/min.
When Pr. 295 = "10"
1 click
*One rotation of the setting dial equals to 24 clicks (24 dial gauges).
REMARKS
 When machine speed display is selected with Pr. 37, the minimum increments of the magnitude of change is determined by Pr.
295 as well. Note that the setting value may differ as speed setting changes the set machine speed and converts it to the speed
display again.
 When the set speed is 100 or more, speed is displayed in 0.1 increments. Therefore, the minimum varying width is 0.1 even
when Pr. 295  0.1.
 When the machine speed setting is 1000 or more, speed is displayed in 1 increments. Therefore, the minimum varying width is
1 even when Pr. 295  1.
NOTE
 For Pr. 295 , unit is not displayed .
 This parameter is valid only in the set speed mode. When other speed-related parameters are set, it is not activated.
 While the frequency setting is being selected, setting "10" changes the frequency setting in 10Hz increments. Be
cautions of the excess speed. (in potentiometer mode)
Parameters referred to
Pr. 37 Speed display
Pr. 144 Speed setting switchover
Setting the parameter unit and operation panel
Initial Value
0
Refer to page 132.
Refer to page 132.
Setting
Range
0
Function invalid
0.01 
The minimum varying width when the set
0.1 
speed is changed by the setting dial can be
1
set.
10
1 click
Description
1 click