LSI 3ware 9750 User Manual page 80

Sata plus sas raid controller card familty, software
Hide thumbs Also See for 3ware 9750:
Table of Contents

Advertisement

Chapter 6. Configuring Your Controller
68
Determines whether the auto-carving policy is enabled or
Auto-Carving.
disabled. When it is enabled, when a new unit is created, any unit larger
than a specified size (known as the carve size) is broken into multiple
volumes that can be addressed by the operating system as separate
volumes. The default carve size is 2 TB.
This auto-carving feature is sometimes referred to as multi-LUN, where
each volume that is created is referred to as a "LUN."
(Referred to as Carving Factor in 3BM) Sets the size for
Carve Size.
dividing up units into volumes when Auto-Carving is enabled and a unit
is created. This setting can be between 1024 GB and 32768 GB.
Changing this setting has no effect on existing units.
Staggered spin-up.
Standby power management state to minimize in-rush current at power-up
and to allow the controller to sequence the spin-up of drives. Compatible
drives are sent a spin up command based on the settings specified with the
policies
Number of drives per spin-up
. These policies can only be set using 3BM or the CLI.
settings
This policy does not apply to drives attached to an expander.
Note:
Number of drives per spin-up.
the same time when the controller is powered up, if staggered spin-up
is enabled. From 1 to x, depending on the number of ports on the
controller.
Delay between spin-up.
groups that spin up at one time on this particular controller, if
staggered spin-up is enabled.
Delay before spin-up.
before the first set of drives on this particular controller will start to
spin-up.
It is possible to enable or disable automatic detection of drives on the
controller's ports for staggered spinup during hot swapping of drives. This
feature is only available in the CLI using the autodetect=on|off command.
For more information, refer to /cx set autodetect=on|off disk=<p:-p>|all
in the3ware SATA+SAS RAID Controller Card CLI Guide, Version 10.2.
Export unconfigured disks (JBOD).
9750 controllers.
Staggered method.
ATA-6 or SATA OOB (Out Of Band). By default, when Staggered Spin-
up is enabled, the OOB scheme is used. If your drives support the SATA
ATA-6 method, select that method in 3BM. There is no electronic method
for the controller to know if a drive supports this method, so it must be set
manually. For staggering to work properly, the drives must support the
3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.2
Spin-up allows drives to be powered-up into the
and
Number of drives that will spin up at
The delay time (in seconds) between drive
(3BM only) The delay time (in seconds)
This setting is not applicable for
Indicates whether the type of staggered spin-up is
Delay between spin-up

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents