0032 Spare capacity too small
0033 Migration started
0034 Migration failed
www.lsi.com/channel/products
Event Type
Warning
Cause
There is a valid hot spare but the capacity is not sufficient to use it for a drive
replacement in existing units.
Action
Replace the spare with a drive of equal or larger capacity than the existing
drives.
Event Type
Information
Cause
The 3ware RAID controller has started the migration of a unit.
Migration changes can include:
Expanding capacity of a unit by adding drives
Changing RAID levels, for example, from RAID 1 to RAID 5
See Also
"RAID Level Migration (RLM) Overview" on page 116
Event Type
Error
Cause
The migration of a unit has failed.
Migration changes can include:
Expanding capacity of a unit by adding drives.
Changing RAID levels, for example, from RAID 1 to RAID 5