LSI 3ware 9750 User Manual page 269

Sata plus sas raid controller card familty, software
Hide thumbs Also See for 3ware 9750:
Table of Contents

Advertisement

002E Replacement drive capacity too small
002F Verify not started; unit never initialized
www.lsi.com/channel/products
It is recommended that you execute a file system check when the rebuild
completes.
Under Windows, right-click on your drive icon and choose
Tools >> Check Now.
For Mac OS X, you can use the First Aid tab in the Disk Utility—select the
disk on the left and then click Verify Disk. If verification encounters
problems, you can then use the Repair Disk option on the same screen.
Under Linux and FreeBSD use the fsck command.
For OpenSolaris and VMware you should follow your operating system's
guide to perform a file system check.
See Also
"Starting a Verify Manually" on page 152
"Enabling or Disabling Auto-Verify for a Unit" on page 107
"Setting Overwrite ECC (Continue on Source Error When Rebuilding)" on
page 108
Event Type
Error
Cause
The storage capacity of the drive you are using as a replacement drive is too
small and cannot be used.
Action
Use a replacement drive equal to or larger than the drives already in use
Event Type
Warning
Cause
A verify operation has been attempted by the 3ware RAID controller, but the
unit has never been initialized before. The unit will automatically transition to
initializing mode and then start a verify.
Error and Notification Messages
Properties >>
257

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents