LSI 3ware 9750 User Manual page 296

Sata plus sas raid controller card familty, software
Hide thumbs Also See for 3ware 9750:
Table of Contents

Advertisement

Chapter 12. Troubleshooting
8024 Enclosure temp above operating
8025 Enclosure temp removed
8026 Enclosure temp added
284
Event Type
Error.
Cause
Applies to 9750 and 9690SA controllers.
The enclosure temperature is above the enclosure manufacturer's specified
operating temperature.
Action
Make sure that the fans are operational. Check for blocked ventilation in the
enclosure and the operating environment.
Continued operation of the enclosure at high temperatures may lead to data
loss and operational failure.
Event Type
Warning.
Cause
Applies to 9750 and 9690SA controllers.
The temperature sensor in the enclosure has been removed or has failed and
the enclosure temperature is no longer being monitored.
Action
The temperature sensor should be replaced or repaired. This may require
specialized skills. Contact your enclosure manufacturer for more information.
Event Type
Information.
Cause
Applies to 9750 and 9690SA controllers.
A temperature sensor has been added to the enclosure or an existing sensor
has been plugged in. This error message can occur due to a poor connection.
3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.2