LSI 3ware 9750 User Manual page 167

Sata plus sas raid controller card familty, software
Hide thumbs Also See for 3ware 9750:
Table of Contents

Advertisement

www.lsi.com/channel/products
A RAID 50 unit can sustain multiple drive failures, as long there is only one
failed drive in each RAID 5 set.
A RAID 6 unit can have two simultaneous drive failures, before becoming
inoperable.
When a redundant RAID unit is running in Degraded mode and you rebuild it,
the missing data is reconstructed from all functioning drives.
Note:
If a rebuild fails, check the Alarms page for the reason. If there was an ECC
error on the source disk, you can force the rebuild to continue by checking the
Overwrite ECC policy on the Controller Settings page in 3DM2 and then running
Rebuild again. This will cause uncorrectable blocks to be rewritten and the data
may be incorrect. It is recommended that you execute a file system check when the
rebuild completes.
Under Windows, you can do this by right-clicking on the Drive and choosing
Properties; then on the Tools tab, click Check Now.
Under Linux or FreeBSD use
On Mac OS X, you can do this using the First Aid tab in the Disk Utility—select
the disk on the left and then click Verify Disk. If verification encounters
problems, you can then use the Repair Disk option on the same screen.
For OpenSolaris and VMware you should follow your operating system's guide
to perform a file system check.
Rebuilding a Unit Through 3DM2
When a drive on a unit becomes defective, you replace it with an available
drive and then rebuild the unit. If Auto-Rebuild is enabled and a drive is
available, starting the rebuild is optional as it will start automatically.
To rebuild a unit through 3DM2
1
If necessary, add a new drive to replace the failed drive. (For details, see
"Adding a Drive" on page 129.)
2
In 3DM2, choose
Management >> Maintenance
3
In the
Unit Maintenance
degraded unit and click the
4
When a dialog box displays available drives, select the drive you want to
replace the failed drive and click
Figure 74. Selecting a Drive when Rebuilding
fsck
section of the Maintenance page, select the
Rebuild Unit
button.
.
OK
Background Tasks
.
155

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents