LSI 3ware 9750 User Manual page 223

Sata plus sas raid controller card familty, software
Hide thumbs Also See for 3ware 9750:
Table of Contents

Advertisement

www.lsi.com/channel/products
Warning:
Physically removing drives which are not in hot swap bays can result in
a system hang, data loss, or may even damage the system and the drive.
Maintenance Task Buttons for Existing Units
Below the list of units, a row of task buttons lets you perform maintenance
and configuration tasks related to the unit. Before clicking one of these
buttons, select the appropriate unit.
Puts the selected unit in verifying mode. If the Advanced Verify
Verify Unit.
schedule is selected on the Scheduling page, the unit will not start actively
verifying until the scheduled time, and the status will indicate "Verify-
Paused." (The Unit Details page will indicate whether a unit is actively
verifying.) If the Basic Verify schedule is active, clicking
the verification process, and verify will begin within approximately 10 to 15
minutes.
If the unit you selected to verify is a redundant unit, the redundancy of the unit
will be verified. For example, it will check parity for a RAID 5 or check data
consistency for a RAID 1. If the unit you checked is not a redundant unit,
verify will do a surface scan of the media. During verification, I/O continues
normally. For RAID 0 and single disks, there is only a slight performance
loss. For redundant units, you can set the background task rate on the
Controller Settings page to specify whether more processing time should be
given to verifying or to I/O. For more information, see "About Verification"
on page 149 and "Setting Background Task Rate" on page 162.
While a unit is verifying, the status changes to Verifying and a
link appears in the right-most column of the Unit Maintenance table.
Note:
If the unit has not previously been initialized and you click Verify Unit, the
initialization process starts. Initialization cannot be halted, so no Stop Verify link
appears. (Initialization can be paused, however, through Scheduling. Initialization
follows the Rebuild/Migrate schedule, so turning on scheduling for Rebuild/Migrate
will pause initialization, as well.) For more information about initialization, see
"About Initialization" on page 146.
Rebuild Unit.
Replaces a failed drive in a degraded unit with an available
drive and begins rebuilding the RAID. When you select a degraded unit and
click
Rebuild Unit
, a dialog box listing available drives appears, so that you
Maintenance page
Verify Unit
begins
Stop Verify
211