Edge Trigger

An edge trigger determines whether the oscilloscope finds the trigger point on the
rising or the falling edge of a signal. Select Edge trigger Mode to trigger on Rising
edge, falling edge or rising & falling edge.
Figure 2-40 Table 2-21 The Trigger menu
Menu
Source
Slope
Sweep
Set up
2-36
Settings
Comments
CH1
Select CH1 as trigger source.
CH2
Select CH2 as trigger source.
CH3
Select CH3 as trigger source.
CH4
Select CH4 as trigger source.
EXT
Select EXT TRIG as trigger source.
EXT/5
Select attenuated EXT TRIG/5 as
trigger source.
AC Line
Select power line as trigger source.
Rising edge
Trigger on rising edge.
Falling edge
Trigger on falling edge.
Rising &
Trigger on both ring & falling edge.
Falling edges
Auto
Acquire waveform even no trigger
occurred.
Normal
Acquire
occurred.
Single
When trigger occurs, acquire one
waveform then stop.
To go to Set Up menu, see table 2-36
User's Guide for DS1000B series
waveform
when
trigger