Data Register Allocation - Blocks 10-19 Ch0 Program Parameters (Shot Action) - IDEC FC5A-F2M2 User Manual

Fc5a series microsmart pentra pid module
Table of Contents

Advertisement

D
A
PID M
EVICE
LLOCATION OF

Data Register Allocation - Blocks 10-19 CH0 Program Parameters (SHOT Action)

When CH0 control is in program control mode, block 10 to 19 should be configured. A maximum of ten steps
from step 0 to step 9 can be configured. All parameters of block 10 to 19 are shown in the following tables. For
detail about each parameter, see page 5-23.
Offset from the Control Register
Step 0
Step 1
Step 2
+180
+201
+181
+202
+182
+203
+183
+204
+184
+205
+185
+206
+186
+207
+187
+208
+188
+209
+189
+210
+190
+211
+191
+212
+192
+213
+193
+214
+194
+215
+195
+216
+196
+217
+197
+218
+198
+219
+199
+220
+200
+221
Offset from the Control Register
Step 5
Step 6
Step 7
+285
+306
+286
+307
+287
+308
+288
+309
+289
+310
+290
+311
+291
+312
+292
+313
+293
+314
+294
+315
+295
+316
+296
+317
+297
+318
+298
+319
+299
+320
+300
+321
+301
+322
+302
+323
+303
+324
+304
+325
+305
+326
5-22
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
ODULE
Step 3
Step 4
+222
+243
+264
Set point (SP)
+223
+244
+265
Step time
+224
+245
+266
Wait value
+225
+246
+267
Proportional term
+226
+247
+268
Integral time
+227
+248
+269
Derivative time
+228
+249
+270
ARW (Anti-Reset Windup)
+229
+250
+271
Output manipulated variable rate-of-change
+230
+251
+272
Alarm 1 value
+231
+252
+273
Alarm 2 value
+232
+253
+274
Alarm 3 value
+233
+254
+275
Alarm 4 value
+234
+255
+276
Alarm 5 value
+235
+256
+277
Alarm 6 value
+236
+257
+278
Alarm 7 value
+237
+258
+279
Alarm 8 value
+238
+259
+280
Reserved
+239
+260
+281
Output manipulated variable upper limit
+240
+261
+282
Output manipulated variable lower limit
+241
+262
+283
Cooling proportional band
+242
+263
+284
Overlap/Dead band
Step 8
Step 9
+327
+348
+369
Set point (SP)
+328
+349
+370
Step time
+329
+350
+371
Wait value
+330
+351
+372
Proportional term
+331
+352
+373
Integral time
+332
+353
+374
Derivative time
+333
+354
+375
ARW (Anti-Reset Windup)
+334
+355
+376
Output manipulated variable rate-of-change
+335
+356
+377
Alarm 1 value
+336
+357
+378
Alarm 2 value
+337
+358
+379
Alarm 3 value
+338
+359
+380
Alarm 4 value
+339
+360
+381
Alarm 5 value
+340
+361
+382
Alarm 6 value
+341
+362
+383
Alarm 7 value
+342
+363
+384
Alarm 8 value
+343
+364
+385
Reserved
+344
+365
+386
Output manipulated variable upper limit
+345
+366
+387
Output manipulated variable lower limit
+346
+367
+388
Cooling proportional band
+347
+368
+389
Overlap/Dead band
FC5A MicroSmart PID Module User's Manual FC9Y-B1283