IDEC FC5A-F2M2 User Manual page 61

Fc5a series microsmart pentra pid module
Table of Contents

Advertisement

D
A
PID M
EVICE
LLOCATION OF
+73
+150
Alarm 1 Hysteresis
+74
+151
Alarm 2 Hysteresis
+75
+152
Alarm 3 Hysteresis
+76
+153
Alarm 4 Hysteresis
+77
+154
Alarm 5 Hysteresis
+78
+155
Alarm 6 Hysteresis
+79
+156
Alarm 7 Hysteresis
+80
+157
Alarm 8 Hysteresis
+81
+158
Alarm 1 Delay Time
+82
+159
Alarm 2 Delay Time
+83
+160
Alarm 3 Delay Time
+84
+161
Alarm 4 Delay Time
+85
+162
Alarm 5 Delay Time
+86
+163
Alarm 6 Delay Time
+87
+164
Alarm 7 Delay Time
+88
+165
Alarm 8 Delay Time
+89
+166
AT Bias
+90
+167
Control Mode
Program Control Mode Start
+91
+168
Type
+92
+169
Step Time Unit
+93
+170
Program End Action
+94
+171
Proportional Term
Cooling Method
+95
+172
(CH0 only)
Set Point (SP) when Program
+96
+173
Control Starts
+97
+174
Number of Repeats
Cooling Output ON/OFF
+98
+175
Hysteresis
(CH0 only)
Output Type
+99
+176
(FC5A-F2M2 only)
External SP Input Bias
+100
+177
(CH1 only)
External SP Input Linear
+101
+178
Conversion Maximum Value
(CH1 only)
External SP Input Linear
+102
+179
Conversion Minimum Value
(CH1 only)
5-20
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
ODULE
When input range unit is Celsius:
0.1 to 100.0°C
When input range unit is Fahrenheit:
0.1 to 100.0°F
When input is voltage or current input:
1 to 1000
0 to 10000 sec
When input range unit is Celsius:
0 to 50 °C (0.0 to 50.0°C for input with decimal point)
When input range unit is Fahrenheit:
0 to 100 °F (0.0 to 100.0°F for input with decimal point)
0: Fixed value control mode
1: Program control mode
0: PV start
1: PVR start
2: SP start
0: Minute
1: Second
0: Terminate program control
1: Continue program control (Repeat)
2: Hold program control
0: Proportional band
1: Proportional gain
0: Air cooling
1: Oil cooling
2: Water cooling
When input is thermocouple or resistance thermometer:
Set point (SP) lower limit to set point (SP) upper limit
When input is voltage or current input:
Linear conversion min. to linear conversion max.
0 to 10000 times
When input range unit is Celsius:
0.1 to 100.0°C
When input range unit is Fahrenheit:
0.1 to 100.0°F
When input is voltage or current input:
1 to 1000
0: Non-contact voltage output (for SSR drive)
1: Current output
±20% of the external SP input linear conversion span
External SP input Linear conversion min. to input range
upper limit
Input range lower limit to external SP input linear conversion
max.
FC5A MicroSmart PID Module User's Manual FC9Y-B1283
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W