3-7. Adjustments

3-7-1. Transparent/Reflective Sensor Position Adjustment

When you replace one of the following parts, perform sensor position adjustment and sensor
sensitivity adjustment as shown below.
Parts replaced
SA Main PCB
SA Adjust Sensor U
(transparent sensor)
SA Adjust Sensor L
(Reflective sensor))

(1) Sensor position adjustment (Factory mode)

After entering Factory mode, adjust the following submenu items:
For details, refer to
- Through Pos (When the "SA Adjust Sensor U" (Transparent sensor) or the "SA Main
PCB" is replaced.)
- Reflect Pos (When the "SA Adjust Sensor L" (Reflective sensor) or the "SA Main PCB" is
replaced.)

(2) Sensor sensitivity adjustment (Factory mode)

Since Factory mode menu includes essential items that can affect the printing
accuracy, etc, DO NOT change the factory set values unless otherwise required.
- Do not turn OFF the power of the printer until you finish the adjustment. If
it is turned OFF, you need to repeat the adjustment from the beginning.
- The value adjusted here is retained until you change it with the same
procedure. Even if you perform initialization by selecting "Test Mode" main
menu, "Factory Default" submenu and then "Yes", the changed value is
not returned to the initial value set at the factory.
Perform sensitivity adjustment for each sensor with the following submenu.
Submenu
- SA Adjust Sensor U (Transparent sensor)
Init Thru Sen
- SA Main PCB
- SA Adjust Sensor L (Reflective sensor)
Init Refl Sen
- SA Main PCB
Refer to
"2-3-3. Factory/Service
Sensor position adjustment
Through Pos, Reflect Pos,
and Fix-Refl Pos
Through Pos
Reflect Pos
"2-3-3. Factory/Service
Adjust when the following part is replaced.
mode" in Chapter 2 for menu operation in Factory mode.
Chapter 3 Disassembly and Maintenance
Sensor sensitivity adjustment
Init Thru Sen and Init Refl Sen
Init Thru Sen
Init Refl Sen
mode" in Chapter 2.
Caution
3-27
3-7 Adjustment
Refer to
(2-1)
(2-2)
CL-S400DT