Citizen CL-S400DT Technical Manual page 89

Thermal label & barcode printer
Hide thumbs Also See for CL-S400DT:
Table of Contents

Advertisement

11. Removal of the "Cam Adjust Head Spring":
1) Turn the "Cam Adjust Head Spring" (Media width adjustment dial) unit it stops to the
direction where the dial number increases. (Refer to the following figure.)
* The dial stops as its groove end reaches the stopper.
2)
Float the "Cam Adjust Head Spring" (dial) by hand over the stopper and further turn it in
the same direction to set it free. Now, it can be removed.
Groove of the dial
12. Remove 1 "Washer, Platen" and detach the "Cam Adjust Head Angle".
13. Remove 2 screws (BHT (PT), M2x5) and detach the "Stopper Cover Open".
14. Remove 2 screws (BH (N), M3x6 (NI)) and detach the "Plate Label Protect 2".
15. Remove the "Stopper Guide Paper U" and 4 "Leg, Case L F" from the "SA Cover Frame".
Stopper Cover Open
SA Cover Frame
Leg, Case L F
Plate Label
Protect 2
Spring Head L
BH (N), M3x6 (NI)
Spacer Adjust Spring
Plate Adjust Spring Holder
SA Plate Holder Head
Plate Label Protect
Float the dial
here.
Stopper
BHT (PT), M2x5
A
BH (N), M3x6 (NI)
Chapter 3 Disassembly and Maintenance
3-6 Disassembly, Reassembly and Lubrication
Stopper
Groove of the dial
Washer, Platen
Cam Adjust Head Angle
(Media thickness adjustement dial)
(FLOIL G-311S)
(FLOIL G-311S)
Leg, Case L F
Spring Head R
Spacer Adjust Head Angle
"SA Plate Holder Head" Block
3-25
Turn further and
remove the dial.
Cam Adjust Head Spring
(Media width adjustment dial)
Stopper Guide Paper U
CL-S400DT

Advertisement

Chapters

Table of Contents
loading

Table of Contents