Signal Line And Pin Assignment; Parallel Port Status Signals When An Error Occurs - Citizen CL-S400DT Technical Manual

Thermal label & barcode printer
Hide thumbs Also See for CL-S400DT:
Table of Contents

Advertisement

(2) Signal line and pin assignment

Pin No. Signal name
1
STROBE
2-9
DATA0-7
10
ACKNLG
11
BUSY
12
PERROR
13
SELECT
14
AUTOFD
15
NC
16
SGND
17
FGND
18
P.L.H
19-30
GND
31
PRIME
32
FAULT
33
GND
34
NC
35
FUSE
36
SELECTIN

(3) Parallel port status signals when an error occurs

The following table shows the status signal change when an error occurs.
Error
Paper end
Error other than paper end
• Head open
• Other
Conditions for Busy
I/O
Input
Strobe signal to read in 8-bit data
Input
8-bit parallel signal
Output
8-bit data request signal
Output
Signal specifying printer busy
Output
Signal specifying media end
Output
Signal specifying if the printer is on-line (printing enabled)
or off-line
Input
Invalid (ignored)
---
Not used
---
Signal ground
---
Frame ground
Output
Peripheral logic high (pulled up to +5V at 10KΩ)
---
Ground for twisted pair return
Input
Printer reset
Output
Signal specifying printer error
---
Signal ground
---
Not used
---
Not used
Input
Invalid (ignored)
L → H
Busy:
L → H
PError:
H → L
Select:
H → L
Fault:
L → H
Busy:
L → unchanged
PError:
H → L
Select:
H → L
Fault:
• Receive buffer full
• Data being read
• Error
2-49
Chapter 2 Operating Principles
Function in Compatible Mode
Compatible mode
2-4. Interface
CL-S400DT