ADJ : Threshold Value Fine Adjustment Mode
Refer to p.19~ for setting procedure
L/D: Output Operation Setting Mode
Refer to p.22 for setting procedure
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
This mode allows fine adjustment of the 'threshold value' setting.
When the incident light intensity display has been selected, the threshold value
can be adjusted in increments as low as a one digit.
When the percentage display has been selected, the threshold value can be
adjusted in increments of one digit (varies depending on the 'threshold value').
However, when FX-305(P) is in window comparator mode, the percentage display
function cannot be utilized.
* The factory setting is; FX-301(P): 40, FX-301(P)-HS: 80,
FX-305(P) output 1: 80, FX-305(P) output 2: 120.
This mode allows the selection of output operation from either L-ON (Light-ON), or
D-ON (Dark-ON).

When using FX-301(P)(-HS) or FX-305(P) normal mode

When set to 'L-ON', the output will be ON if the incident light intensity becomes
greater than the 'threshold value'.
When set to 'D-ON', the output will be ON if the incident light intensity becomes
less than the 'threshold value'.
Output operation
L-ON
OFF
ON
D-ON
0
0
Threshold value

When using FX-305(P) window comparator mode

When set to 'L-ON', if the incident light intensity is between the two 'threshold
value' levels, the output will be ON. If the incident light intensity is outside of the
two threshold value levels, the output will be OFF.
When set to 'D-ON', if the incident light intensity is between the two 'threshold
value' levels, the output will be OFF. If the incident light intensity is outside of the
two threshold value levels, the output will be ON.
Output operation
L-ON
OFF
ON
D-ON
0
0
* The factory setting is L-ON (Light-ON).
When using rising differential mode
For L-ON, output is ON for a constant period of time when the incident light
intensity is rising.
For D-ON, output is OFF for a constant period of time when the incident light
intensity is rising.
Incident
light
intensity
Output
operation
ON
L-ON
T
T
OFF
ON
D-ON
OFF
When using trailing differential mode
For L-ON, output is ON for a constant period of time when the incident light
intensity is trailing.
For D-ON, output is OFF for a constant period of time when the incident light
intensity trailing.
Incident
light
intensity
Output
operation
ON
L-ON
T
T
OFF
ON
D-ON
OFF
8
ON
OFF
Incident light intensity
4,000 / 9,999
ON
OFF
OFF
ON
Incident light intensity
4,000 / 9,999
Threshold
Threshold
value 1
value 2
* The output time 'T' can be set by changing
the timer period in timer setting mode
(initial value: 10 ms).
Time
T
T
* The output time 'T' can be set by changing
the timer period in timer setting mode
(initial value: 10 ms).
Time
T
T