5

PRO1 Mode

5-1. PRO1 Mode Functions and Settings

PRO1 mode is used mainly for configuring the details of basic settings.
: Response Time Change Function
Refer to p.27 for setting procedure
: Timer Setting Function
Refer to p.28~ for setting procedure
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
The response times for the FX-301(P)(-HS) can be switched among five levels:
H-SP (ultra high-speed), FAST (high-speed), S-D (reduced intensity), STD (standard)
and LONG (long-range). The FX-305(P) can be switched among six levels: the same
as above without the S-D (reduced intensity) level but with STDF (standard 2) and
U-LG (ultra long-range) levels. (The switching of response times among these levels
will cause corresponding changes to the sensing range.)
* FX-301(P)(-HS):The factory setting is 'STD (standard)'.
FX-305(P): The factory setting is 'STDF (standard 2)'.
Model No.
Mode
FX-301(P)-HS
(ultra high-speed)
(high-speed)
(reduced intensity)
(standard)
(standard 2)
(long-range)
(ultra long-range)
Note: If the interference prevention function is set to
(Ultra high-speed) : when performing sensing of ultra high-speed objects
*
(high-speed)
: when performing sensing of high-speed objects
(reduced intensity): suitable for when the received light is saturated due to too
short a setting distance, and for delicate sensing when
sensing translucent objects, etc.
(standard)
: standard setting
(standard 2)
: The incident light intensity for standard settings can be set to
up to 9,999 [digit]
(long-range)
: when long sensing range is required
(ultra long-range) : when a longer sensing range than for
P.28
FX-301(P)(-HS)
Four different timer operations can be selected; Without timer / OFF-delay / ON-
delay / ONE SHOT. The available timer periods are 0.5 ms and 1 to 9,999 ms.
* The settings allow timer operation to be switched among Without timer / OFF-
delay / ON-delay / ONE SHOT timer when in 'NAVI mode'.
FX-305(P)
P.29
For output 1, six different timer operations can be selected: Without timer / OFF-
delay / ON-delay / ONE SHOT / ON-delay • OFF-delay / ON-delay • ONE SHOT.
For output 2, four different timer operations can be selected: Without timer / OFF-
delay / ON-delay / ONE SHOT.
The range of available timer periods is;
Output 1: 0.5 ms, 1 to 9,999 ms
Output 2: 0.5 ms, 1 to 500 ms
* The settings allow timer operation to be switched among Without timer / OFF-
delay / ON-delay / ONE SHOT / ON-delay • OFF-delay / ON-delay • ONE SHOT
when in 'NAVI mode'.
24
Response time
FX-301(P)
35 !s
65 !s
150 !s
150 !s
250 !s
250 !s
250 !s
250 !s
2 ms
2 ms
, the response time will become doubled.
FX-305(P)(Note)
65 !s
150 !s
250 !s
700 !s
2.5 ms
4.5 ms
is required.