8-3. Remote Data Bank Load Setting Function [Except FX-301(P)-HS]
By utilizing optical communication, settings within the data banks of each connected amplifier can be loaded all at
once. However, channel data will not be loaded for FX-301(P) and FX-305(P) units in which the optical
communication setting function has been locked.
Please refer to p.43
The optical communications function
Turn the Jog switch to select the desired
channel for loading for all amplifiers at once.
Channel 1
Displayed on
amplifiers on which
communication is
being done.
The digital display will blink
twice to confirm the setting.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Press the MODE
key 5 times.
Turn the Jog switch
4 times toward the
'
' direction.
Press the
Jog switch.
Turn the Jog switch
once toward the
'
' direction.
Press the
Jog switch.
Channel 2
Channel 3
Press the
Jog switch.
Press the
Jog switch.
The digital display
will scroll (twice).
Press the MODE key
3 times or keep it pressed
for 2 sec. or more.
for the direction of optical communication.
1 Press the [MODE key] 5 times to select 'PRO mode'.
2 Turn the [Jog switch] 4 times toward the '
select 'PRO4 mode'.
3 Press the [Jog switch] to enter the 'setting condition copy
setting' state.
4 Turn the [Jog switch] once toward the '
the 'remote data bank load setting' state.
5 If the [Jog switch] is pressed, the digital display will blink.
6 Turn the [Jog switch] to select the desired 'channel' for
loading for all amplifiers at once.
7 If the [Jog switch] is pressed, the letters '
8If the [Jog switch] is pressed while '
digital display will scroll (twice) and the settings information
will be loaded for all amplifiers at once. Then '
blink twice, confirming the setting.
However, for amplifiers [FX-301(P) or FX-305(P)] in
which the optical communications settings change
function has been locked, '
9 Press the [MODE key] 3 times or keep it pressed for 2 sec.
or more, the amplifier will return to 'RUN mode' (normal
sensing operation).
45
' direction, to
' direction, to enter
' will blink.
' is blinking, the
' will
' will blink twice.

Advertisement