5-5. Hysteresis Function

This function selects the hysteresis from among three different levels (small / standard / large).
H-01
(small)
Turn the Jog switch to select
the desired hysteresis.
The digital display will quickly
blink 3 times to confirm the setting.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Press the MODE key
5 times.
Turn the Jog switch
once toward
the '
' direction.
Press the
Jog switch.
Turn the Jog switch
twice toward
the '
' direction.
Press the
Jog switch.
H-02
H-03
(standard)
(large)
Press the
Jog switch.
Press the MODE key
3 times or keep it pressed
for 2 sec. or more.
1Press the [MODE key] 5 times to select 'PRO mode'.
2 Turn the [Jog switch] once toward the '
to select 'PRO1 mode'.
3 Press the [Jog switch] to enter the 'response time change'
state.
4 Turn the [Jog switch] twice toward the '
to enter the 'hysteresis setting' state.
5 If the [Jog switch] is pressed, the current
'hysteresis' level will be displayed.
* The factory setting is 'H-02 (standard)'.
6 If the [Jog switch] is turned, the digital display will blink.
Select the desired 'hysteresis' level.
7If the [Jog switch] is pressed, the digital display will quickly
blink 3 times, confirming the 'hysteresis' setting.
8 Press the [MODE key] 3 times or keep it pressed for 2 sec.
or more, the amplifier will return to 'RUN mode' (normal
sensing operation).