Remote Data Bank Save Setting Function - Sunx FX-301 Operation Manual

Digital fiber sensor.
Hide thumbs Also See for FX-301:
Table of Contents

Advertisement

8-4. Remote Data Bank Save Setting Function [Except FX-301(P)-HS]
This function allows the current configuration setting information for all connected amplifiers to be saved into the respective data banks.
Up to 3 sets of configuration settings information can be saved into each amplifier, using '
However, units in which the optical communications settings change function has been locked, saving will not occur.
Please refer to p.43
The optical communications function
Turn the Jog switch to select the desired
channel for saving for all amplifiers at once.
Channel 1
Displayed on
amplifiers on which
communication is
being done.
The digital display will blink twice
and the procedure will be complete.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Press the MODE
key 5 times.
Turn the Jog switch
4 times toward the
'
' direction.
Press the
Jog switch.
Turn the Jog switch
twice toward the
'
' direction.
Press the
Jog switch.
Channel 2
Channel 3
Press the
Jog switch.
Press the
Jog switch.
The digital display
will scroll (twice).
Press the MODE key
3 times or keep it pressed
for 2 sec. or more.
for the direction of optical communication.
1 Press the [MODE key] 5 times to select 'PRO mode'.
2 Turn the [Jog switch] 4 times toward the
select 'PRO4 mode'.
3 Press the [Jog switch] to enter the 'setting condition copy
setting' state.
4 Turn the [Jog switch] twice toward the
the 'remote data bank save setting' state.
5 If the [Jog switch] is pressed, the digital display will blink.
6 Turn the [Jog switch] to select the desired 'channel' for
saving for all amplifiers at once.
7 If the [Jog switch] is pressed, the letters '
8If the [Jog switch] is pressed while '
digital display will scroll (twice) and the settings information
will be saved for all amplifiers at once. Then '
blink twice and the procedure will be complete.
However, for amplifiers in which the optical communi-
cations settings change function has been locked,
'
' will blink twice.
9Press the [MODE key] 3 times or keep it pressed for 2 sec.
or more, the amplifier will return to 'RUN mode' (normal
sensing operation).
46
' , '
' and '
' .
direction, to
'
'
'
'
direction, to enter
' will blink.
' is blinking, the
' will

Advertisement