Advertisement

4-5. Threshold Value Fine Adjustment Mode [when using FX-305(P) window comparator mode]
This mode allows fine adjustment of the 'Threshold value (1_SL, 2_SL)' setting.
Turn the Jog switch to select either
upper limit or lower limit.
Setting for 1_SL
Select '1_SL'.
Turn the Jog switch to set
the desired threshold value.
In case of
changing
threshold value
to 85.
The digital display will quickly
blink 3 times to confirm the value.
To be continued on the next page
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Press the
MODE key twice.
Output 1
Press the
Jog switch.
Press the
Jog switch.
Refer to p.21
for 2_SL settings.
Press the
Jog switch.
Press the
Jog switch.
Turn the
Jog switch.
1 Press the [MODE key] twice to select 'threshold value fine
adjustment mode'.
2 Turn the [Jog switch] to set 'output 1'.
3 Press the [Jog switch] to select 'output 1'.
4The lower limit setting '
'
' will be displayed.
5 Turn the [Jog switch] to select '1_SL'. If the [Jog switch] is
pressed, the threshold value for '1_SL' will be displayed.
If an increased 'threshold value' is desired,
turn the [Jog switch] toward the '
If a decreased 'threshold value' is desired,
turn the [Jog switch] toward the '
6 If the [Jog switch] is pressed, the display will blink quickly
3 times and the threshold value for '1_SL' will be confirmed.
7 '
' is displayed. If the [Jog switch] is turned, then the
upper limit setting '
20
' or the upper limit setting
' direction.
' direction.
' will be displayed.