Output 2 Sensing Mode Settings - Sunx FX-301 Operation Manual

Digital fiber sensor.
Hide thumbs Also See for FX-301:
Table of Contents

Advertisement

10-3. Output 2 Sensing Mode Settings

Output 2 can be set to one of three sensing modes (normal / alarm output / error output).
Turn the Jog switch to select
output 2.
Refer to '10-2. Output 1
Sensing Mode Settings'
on p.56.
Normal mode Alarm output Error output
Turn the Jog switch to
select the desired shift amount.
The digital display will blink quickly
3 times to confirm the selection.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Press the MODE
key 5 times.
Turn the Jog switch 6 times
toward the '
' direction.
Press the
Jog switch.
Press the
Jog switch.
Turn the Jog switch to select
the desired sensing mode.
Press the
Jog switch.
Sets the alarm
output shift amount
Press the
Jog switch.
Press the MODE key
3 times or keep it pressed
for 2 sec. or more.
1 Press the [MODE key] 5 times to select 'PRO mode'.
2
the [Jog switch] 6 times toward the '
Turn
select 'PRO6 mode'.
3 Press the [Jog switch] to enter the 'output 1 / output 2
selection' state.
4
Turn
the [Jog switch] to enter the 'output 2 sensing mode
setting' state.
5 If the [Jog switch] is pressed, the current sensing mode will
be displayed.
* The factory setting is 'normal mode'.
6 If the [Jog switch] is turned, the digital display will blink.
Select the desired 'sensing mode'.
7 If the [Jog switch] is pressed, the digital display will blink
quickly 3 times, confirming the 'sensing mode'.
8 If 'Alarm output mode' is selected, shift amount setting will be
enabled. The level can be set to one of the following eight
levels: 50 %, 30 %, 15 %, 10 %,
50 %.
9 Press the MODE key 3 times or keep it pressed for 2 sec. or
more, the amplifier will return to 'RUN mode' (normal sensing
operation).
58
' direction, to
10 %,
15 %,
30 %,