Sunx FX-301 Operation Manual page 16

Digital fiber sensor.
Hide thumbs Also See for FX-301:
Table of Contents

Advertisement

This is a method of setting the thresh-
2-level Teaching
old values (1_SL, 2_SL) by two levels
(P-1, P-2) teaching.
Select '2-level teaching (
PRO6 mode beforehand.
Setting in PRO6 mode beforehand
Setting in NAVI mode
The status condition when a sensing object is present
that can be used as a baseline for the lower limit.
To be continued on the next page
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
)' in
For further details, refer to '10-2. Output 1 Sensing Mode Settings' on p.56.
Press the
MODE key 5 times.
Turn the Jog switch
6 times toward the
'
' direction.
Turn the Jog switch
to select output 1.
Turn the Jog switch
to select window
comparator mode.
Turn the Jog switch
to select 2-level
teaching.
Press the MODE key
3 times or keep it pressed
for 2 sec. or more.
Press the
MODE key once.
Output 1
Press the
Jog switch.
Press the
Jog switch.
Incident light
intensity of P-1.
15
Incident light intensity
9,999
P-2
2_SL
P-1
1_SL
P-1
P-2
1_SL
2_SL
Output
Output
OFF
ON
OFF
(L-ON)
(L-ON)
1Press the [MODE key] 5 times to select 'PRO mode'.
2Turn the [Jog switch] 6 times towards the '
select 'PRO mode'.
3Turn the [Jog switch] to select 'output 1', and then press
the [Jog switch] to confirm the setting.
4Turn the [Jog switch] to select 'window comparator mode',
and then press the [Jog switch] to confirm the setting.
5Turn the [Jog switch] to select '2-level teaching', and then
press the [Jog switch] to confirm the setting.
1Press the [MODE key] once to select 'TEACH mode'.
2Press the [Jog switch] to select 'output 1'.
3The current teaching method will be displayed, and then the
unit will enter the 'P-1' setting state.
4If the [Jog switch] is pressed while in the status condition
when a sensing object is present that can be used as a
baseline for the lower limit, then the display will blink and
indicate the incident light intensity reading.
When using thru-beam type fiber
• Press the [Jog switch] for the sensing object that has the
greatest amount of interrupted light.
When using reflective type fiber
• Press the [Jog switch] for the sensing object with the
lowest incident light intensity.
Note) Even if procedures 4 and 6 are reversed, teaching for a
sensing object with low incident light intensity will
automatically cause the setting of 'lower limit value 1_SL'.
0
ON
OFF
' direction to
Time